https://www.mdu.se/

mdu.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Model of evapotranspiration and groundwater level based on photovoltaic water pumping system
China Institute of Water Resources and Hydropower Research, Beijing, China.
China Institute of Water Resources and Hydropower Research, Beijing, China.
Mälardalen University, School of Business, Society and Engineering, Future Energy Center.ORCID iD: 0000-0002-1351-9245
Institute of Water Resources for Pastoral Areas, Hohhot, China .
Show others and affiliations
2014 (English)In: Applied Energy, ISSN 0306-2619, E-ISSN 1872-9118, Vol. 136, p. 1132-1137Article in journal (Refereed) Published
Abstract [en]

Photovoltaic (PV) water pumping system has been proved being environmental-friendly and low energy-cost, which has a promising prospect in arid areas which are rich in solar energy resources. However, water resources remain to be one of the main restraints to the application of PV water pumping system widely. Models to evaluate the evapotranspiration and groundwater level in the well are estimated based on the data of a field trip, which was conducted in Wulanchabu grassland, Inner Mongolia, China. Data about the performance of the PV water pumping system, including evapotranspiration and the groundwater level variation were collected. In this paper, evapotranspiration is calculated by Penman-Monteith method and Theis formula is introduced to calculate the soil characters and simulate the groundwater level variation. PRMSE and Nash-Sutcliffe efficiency are used to validate the model performance with the collected lysimeter data and groundwater level. The results show that the modeling of the evapotranspiration and groundwater level is reliable. According to the water demand and energy demand, the method to optimize the pumping system is introduced. Based on the calculated result and collected data of water demand and groundwater level, groundwater in the site is abundant to support the system. However, due to the stickiness of the soil condition, the recharge rate is smaller than the pumping rate. According to the comparison, the current system is oversized. In this condition, the pump would run out of water, and have to stop pumping. Therefore, not only the water quantity is an important factor to be considered, the soil condition and recharge rate are also of great significance to the optimization of photovoltaic water pumping systems.

Place, publisher, year, edition, pages
2014. Vol. 136, p. 1132-1137
Keywords [en]
Evapotranspiration, Groundwater level, Penman-Monteith method, Photovoltaic water pumping system, Theis formula, Groundwater, Photovoltaic water pumping
National Category
Energy Systems
Identifiers
URN: urn:nbn:se:mdh:diva-26643DOI: 10.1016/j.apenergy.2014.05.045ISI: 000345725800108Scopus ID: 2-s2.0-84909586839OAI: oai:DiVA.org:mdh-26643DiVA, id: diva2:766890
Available from: 2014-11-28 Created: 2014-11-28 Last updated: 2017-12-05Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Campana, Pietro EliaYan, Jinyue

Search in DiVA

By author/editor
Campana, Pietro EliaYan, Jinyue
By organisation
Future Energy Center
In the same journal
Applied Energy
Energy Systems

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 86 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf