Hydraulic performance of a new district heating systems with distributed variable speed pumps
Tianjin University, Tianjin, China .
Tianjin University, Tianjin, China .
Tianjin University, Tianjin, China .
Tianjin University, Tianjin, China .
Show others and affiliations
2013 (English)In: Applied Energy, ISSN 0306-2619, E-ISSN 1872-9118, Vol. 112, p. 876-885Article in journal (Refereed) Published
Abstract [en]

The application of distributed variable speed pumps (DVSP) in the district heating (DH) network has been considered as a technology improvement that has a potential of saving energy, compared to the conventional central circulating pump (CCCP) DH system. A hydraulic model was developed to simulate the hydraulic performance of such a DVSP DH system, based on Kirchhoff's laws. It was applied to a real DH network in Kuerle, China. In order to improve the model accuracy, a new parameter called resistance ratio was proposed by comparing the measured data and the simulated result. The validation result shows that the model has the ability to predict the hydraulic behavior of the DVSP system. The results show that when the rotational speeds of all substation pumps are synchronously decreased by the same percentage, the pump heads and the flow rates are also reduced synchronously and almost in the same degree in all loops. In addition, two operation cases of DH were investigated, including (I) the flow rate varies in all of the loops simultaneously, and (II) the flow rate varies only in one of the loops. For both cases, the DVSP system has a better performance of saving energy at least 30% than the CCCP system. Compared to the CCCP system, the installed pump capacities can be smaller in the DVSP system. Hence, applying DSVP, especially at a low flow rate, can save quite much electricity. Based on the example network in Kuerle, the DVSP system consumes electricity 71% and 31% less than the CCCP system for Cases I and II respectively.

Place, publisher, year, edition, pages
2013. Vol. 112, p. 876-885
Keywords [en]
Central circulating pump, Distributed variable speed pump, District heating, Energy saving, Hydraulic performance
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:mdh:diva-21682DOI: 10.1016/j.apenergy.2013.06.031ISI: 000329377800093Scopus ID: 2-s2.0-84884209996OAI: oai:DiVA.org:mdh-21682DiVA, id: diva2:651914
Available from: 2013-09-27 Created: 2013-09-27 Last updated: 2017-12-06Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records BETA

Li, Hailong

Search in DiVA

By author/editor
Li, Hailong
By organisation
Future Energy Center
In the same journal
Applied Energy
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 47 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf