Konstruktion av skyddshuv för röntgenrör till RemaLog X-Ray
Mälardalen University, School of Innovation, Design and Engineering.
2013 (Swedish)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE creditsStudent thesis
Abstract [sv]

Denna rapport kommer av avhandla det examensarbete som genomförts inom civilingenjörsprogrammet innovation och produktdesign på Mälardalens högskola. Arbetet har genomförts på RemaControl Sweden AB och startade den 3:e september 2012 med slutpresentation den 29:e mars 2013.

RemaControl är ett företag som är baserat i Västerås och tillverkar mätsystem till sågverksindustrin. Den produkt som detta projekt har kretsat runt är deras mätsystem som heter RemaLog X-Ray som är ett ”state-of-the-art-system” som använder sig av röntgen för att läsa av mätdata från trästockar när de kommer in på sågverket.

Uppdraget från RemaControl var att omkonstruera den skyddshuv som omsluter röntgenrören. Dess syfte är att skydda miljön utanför mätramen från strålning som röntgenrören genererar. Röntgenrören måste servas vart 6:e månad och för att komma åt röntgenrören så måste man i dagsläget montera bort skyddsramen. Detta är ett moment som tar tid och är slitsamt för servicepersonalens ryggar eftersom den är svåråtkomlig och väger över 25 kg. Anledningen till dess höga vikt är på grund av att den måste vara tillverkad med blyväggar för att stoppa strålningen. Det är även viktigt för sågverken att servicetiden är så kort som möjligt eftersom det minskar tiden som banan behöver stå still, i vilket sågverken förlorar pengar.

För att lösa detta problem så har uppdraget delats upp i olika delproblem som har lösts på olika sätt. Det har tagits fram olika koncept med hjälp av CAD. Dessa koncept har utvärderats och en helhetslösning har tagits fram som uppfyller RemaControls krav.

Utöver detta så har även en prototyp tagits fram för att säkerställa att dess egenskaper uppfyller även alla krav i praktiken.

Abstract [en]

This report contains the thesis work in the civil engineering program of innovation and product design on Mälardalens Högskola, Sweden. This work has been collaboration with RemaControl Sweden AB and it started on September the 5th 2012 and was presented on April the 5th 2013.

RemaControl is a company that is based in Västerås, Sweden, and manufactures measuring systems for the sawmill industry. This project has been focused on their system RemaLog XRay that is a state-of-the-art-system that implements x-ray-technology to retrieve measuring data from incoming logs of wood.

The assignment from RemaControl was to redesign the protective housing that contains the xray tubes. Its purpose is to protect the outside environment from radiation generated from the x-ray tubes. The x-ray tube needs to be maintained every 6 thmonths and to retrieve the x-ray tubes it is necessary to remove the protective housing in its present configuration. This operation puts the service engineers backs in unfavorable positions because it is very inaccessible to retrieve and has a weight of more than 25 kg. The reason for this weight is because that the protective housing needs to be constructed with walls of pure lead to protect the outside environment from the radiation. It is also important for sawmills that the time of the service is as short as possible because it prevents interruption of the runway, from which sawmills loses money.

To solve this assignment the problem has been divided into sub problems that have been solved with different methods. Different concept solutions have been creating using CAD. These concepts have been evaluated and a final solution has been created that meets the requirement from RemaControl.

To ensure that its practical properties are sufficient, a prototype has also been developed.

Place, publisher, year, edition, pages
2013. , p. 125
Keywords [en]
Product development, mechanical construction, x-ray, sawmill, radiation safety
Keywords [sv]
Produktutveckling, mekanisk konstruktion, röntgen, sågverk, strålsäkerhet
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:mdh:diva-19063OAI: oai:DiVA.org:mdh-19063DiVA, id: diva2:623703
External cooperation
RemaControl Sweden AB
Subject / course
Product and Process Development
Uppsok
Technology
Supervisors
Examiners
Available from: 2013-05-30 Created: 2013-05-28 Last updated: 2013-05-30Bibliographically approved

Open Access in DiVA

fulltext(8170 kB)649 downloads
File information
File name FULLTEXT01.pdfFile size 8170 kBChecksum SHA-512
22b167cdb42982a0851fbd1102e7b27814e688a48f6753d4af547e091250a55a42b20b3fcf5a9cc90a42d25f8c42bff68a1c36d268c8e90bb205ea2d94f5d819
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Nordin, Daniel
By organisation
School of Innovation, Design and Engineering
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 650 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 340 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf