https://www.mdu.se/

mdu.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Impact of Radon Ventilation on Indoor Air Quality and Building Energy saving
Mälardalen University, School of Sustainable Development of Society and Technology. (PRO)
2009 (English)Licentiate thesis, comprehensive summary (Other academic)
Abstract [en]

Industrial living is caused much people do live and work in closed and confined places; offices and residential buildings. This is why in this new world more fresh air which is generally provided by forced ventilation plays a vital role in living of human being. Furthermore because of many different indoor pollutants, like radon and artificial pollutants, the amount of fresh air and in turn the energy consumption has increased. This energy consumption related to ventilation has reached up to about 30 percent of energy used of building section. So making interaction between indoor air quality (IAQ) and optimization of energy saving is a necessary work.  Radon as a natural pollutant is occurred in environment and in many countries threatens people health whereas is called the second causes of cancer. For reducing radon concentration in residential building at the acceptable level forced ventilation is used usually. Ventilation can improve IAQ but in the other side would increase the energy consumption in building sector and just now the contribution of ventilation exceeds up 50 percent of building sector's share. The aim of this thesis is to study the impact of ventilation on indoor radon by using Computational Fluid Dynamics (CFD) to achieve indoor air quality and energy efficiency. Application of CFD as a new technology, because of its cost and time savings, and on the other side, of its flexibility and precision is  increasingly grown and can be used as a very important and valuable tool for the prediction and measurement of radon distribution in a ventilated building . Currently, measurement techniques and proposed standards and regulations of indoor pollutants and ventilation, particularly related to indoor radon cannot be able to provide a secure, safe and energy efficient indoor climate. This is why the indoor airflow distribution is very complex and with changing building geometry and operation condition, the treatment of air flow pattern, substantially would be changed, whereas the rules are usually independent of the buildings features. Furthermore, the indoor standards and regulations are based on average amount of pollutants in a room, whereas the pollutant distributions aren't identical and are varied throughout the room. Then the current techniques aren't so exactly valuable and acceptable.

From different methods which is privilege to control pollutants, ventilation method is applicable in existing buildings. Designing effective ventilation can reduce radon concentration to very level low with regarding energy conservation remarks.

 

This thesis presents results from simulation studies on ventilation and radon mitigation in residential buildings, in view points of indoor air quality and energy savings. The CFD technique is applied to predict, visualize and calculate of mixture radon-air flow. The distribution of indoor radon concentration, air velocity and room temperature also have considered together for achieving indoor air quality and energy saving. The results are also compared with the experimental data and related previous works.

 

It was found that with increasing ventilation rate, the radon concentration is decreased, but the location of ventilation system is also important. From the simulation results, it is observed that within the ventilated room, there are some zones, which are good for living and somewhere is more polluted. The traditional radon detectors basically show the average value of radon content in 1m­3 of air. That is why detector measuring is not exact and safe.

 

Simulation results proved that floor heat can be supported ventilation effect and speed up the mixture movement. Floor heating reinforces the buoyancy effect, which is useful to reduce radon content in the floor (seating area) and then lower ventilation rate can be applied.

Place, publisher, year, edition, pages
Västerås: Mälardalen University , 2009. , p. 109
Series
Mälardalen University Press Licentiate Theses, ISSN 1651-9256 ; 109
National Category
Energy Engineering
Research subject
Energy- and Environmental Engineering
Identifiers
URN: urn:nbn:se:mdh:diva-7286ISBN: 978-91-86135-39-3 (print)OAI: oai:DiVA.org:mdh-7286DiVA, id: diva2:237857
Presentation
2009-10-16, U2- 036, Mälardalen University, Västerås, 10:00 (English)
Opponent
Supervisors
Available from: 2009-09-25 Created: 2009-09-25 Last updated: 2010-04-15Bibliographically approved

Open Access in DiVA

fulltext(2135 kB)2150 downloads
File information
File name FULLTEXT01.pdfFile size 2135 kBChecksum SHA-512
a6a9a78b61271f2c76435d4e87eb733022f4a92528fe7334d251c6495af2df64fc42d98b3010a49c5eb24d1db998a78a65a7d9372d6caced81ae7d772ad9fbba
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Akbari, Keramatollah
By organisation
School of Sustainable Development of Society and Technology
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 2154 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

isbn
urn-nbn

Altmetric score

isbn
urn-nbn
Total: 1661 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf