https://www.mdu.se/

mdu.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
PV systems integrated with commercial buildings for local and national peak load shaving in Poland
PUT Univ, Poznan, Poland..
Wroclaw Univ Sci & Technol, Wroclaw, Poland..
PUT Univ, Poznan, Poland..
Mälardalen University, School of Business, Society and Engineering, Future Energy Center.ORCID iD: 0000-0002-1351-9245
2021 (English)In: Journal of Cleaner Production, ISSN 0959-6526, E-ISSN 1879-1786, Vol. 322, article id 129076Article in journal (Refereed) Published
Abstract [en]

A reduction of demand for electrical power in peak periods, commonly called peak shaving, is beneficial for customers from the economic point of view. However, it is also of considerable importance for the National Power System operation in terms of grid stability. This research focuses on the issue of nationwide potential of peak shaving by PV installations in office buildings in Poland. It is assumed that this sector can play a significant role in decreasing the demand for peak power on a large scale. The modelling of office building load was conducted with the use of an Artificial Neural Network. The study took into consideration different tilt and orientation configurations of PV modules as well as their degradation. The impact of peak shaving on the National Power System was assessed on the basis of the monthly peak load balancing factor. The influence of PV installations on grid infrastructure was estimated based on changes in transformer lifetime. The research showed that the optimum PV capacity for an average office building was approximately 600-800 kW(p) with a south orientation and tilt angle of 30 degrees. The highest peak shaving capacity on the country level is observed for PV systems with a south-east orientation. 273.75 MWp in PV capacity reduces the maximum national load by 200 MW in May. The analysed PV system producing electricity for self-consumption, can prolong the lifetime of the overloaded transformer connected to the office building by up to 36%.

Place, publisher, year, edition, pages
ELSEVIER SCI LTD , 2021. Vol. 322, article id 129076
Keywords [en]
Peak shaving, Office building, PV, Polish power system
National Category
Energy Engineering
Identifiers
URN: urn:nbn:se:mdh:diva-56307DOI: 10.1016/j.jclepro.2021.129076ISI: 000705715600003Scopus ID: 2-s2.0-85120970357OAI: oai:DiVA.org:mdh-56307DiVA, id: diva2:1606762
Available from: 2021-10-28 Created: 2021-10-28 Last updated: 2021-12-21Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Campana, Pietro Elia

Search in DiVA

By author/editor
Campana, Pietro Elia
By organisation
Future Energy Center
In the same journal
Journal of Cleaner Production
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 90 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf