ENERGIANVÄNDNING I ETT SMÅHUS FRÅN 50-TALET: Beräkningsresultat med tilläggsisolering, nya fönster och värmepump
Mälardalen University, School of Business, Society and Engineering.
2020 (Swedish)Independent thesis Advanced level (professional degree), 20 credits / 30 HE creditsStudent thesis
Abstract [sv]

The purpose of this project was to map the construction and of a house built in 1953 and calculate the energybalance for the house in its original design. The idea was to investigate the measures that has been taken to lower the energy use in the building and see how great the savings were after each measure in the specific order they were made. The reason for choosing the there is possibility in saving energy in the residential sector  The energybalance were calculated by hand for the building in its original design and the energy efficient measures that were examined was additional insulation of the attic, window replacement and installation of a heat pump. The result for the buildings energybalance is that the demand for active heating is about 20 000 kWh/year. That can be compared with the result for calculation of the original oilfired boiler that were 13 600 kWh/year. The energyefficient measures that were made showed that the additional insulation gave a 11 percent saving of the demand for active heat. windows that were replaced and sealed gave an additional saving of 0,3 percent. That is because the measures of the windows result in two positive effect regarding the transmission- and ventilation losses and one negative effect regarding the passive heat. the measures lower the demand for active heat from 20 000 kWh/year to 17 500 kWh/year. Installation of a heat pump covers 48 percent of all bought energy and covers approximately 10 000 kWh/year of the demand for active heat.  Keywords: energybalance, demand for active heat, heatlosses, passive heat, window, additional insulation, heat pump

Place, publisher, year, edition, pages
2020. , p. 71
National Category
Other Civil Engineering
Identifiers
URN: urn:nbn:se:mdh:diva-49552OAI: oai:DiVA.org:mdh-49552DiVA, id: diva2:1459913
Subject / course
Building Engineering
Supervisors
Examiners
Available from: 2020-08-21 Created: 2020-08-21 Last updated: 2020-08-21Bibliographically approved

Open Access in DiVA

fulltext(5692 kB)1410 downloads
File information
File name FULLTEXT01.pdfFile size 5692 kBChecksum SHA-512
46b958066f3a15c04b12529f5699f318c681ab0dd71a8ff2f7a343047ebb831c737ff6278dc73986ca4a45bf27b473fba01d2a98daffd2e03f71d357cd01a3b5
Type fulltextMimetype application/pdf

By organisation
School of Business, Society and Engineering
Other Civil Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 1410 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 299 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf