Säkerhet mot fortskridande ras för prefabricerade elementväggar: UNDERSÖKNING AV FLERBOSTADSHUS
Mälardalen University, School of Business, Society and Engineering.
2019 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesis
Abstract [en]

Progressive collapses may occur when a bearing wall is eliminated for various reasons. It can be a gas explosion or collision accident of a train or a vehicle, but also during renovation of a building component. After the wall has been eliminated, the building should be undamaged and not suffer a progressive collapse. Such an event can be avoided through a vertical link. The purpose of this study is to examine how secure today's vertical strap’sare against progressive collapse, and to find a solution for reduced risk of collapse Method: This study includes a literature review and a case study. The literature review was performed by a deepening of the existing literature that investigated the progressive collapse and the vertical drag strip. The studies found through the database Google school and Discovery. The case study was conducted in Kadesjös which is an engineering office where drawings and calculations were performed. Result: The result indicates that the vertical strap used today cannot withstand the design load if the entire wall (including the screw attachment) is eliminated. The threaded rod will then be pulled out of the floor and a progressive collapse occurs. By mounting a 70x70mm plate in the floor this can be prevented. Without the plate it takes only 58 kN to pull out the threaded rod from the floor, but with the plate the connection’s capacity is increased to 100 kN and then the anchorage pipe limits the capacity. Conclusion: The conclusion of this thesis is that a plate that increases the vertical strap’s capacity and thereby increases the safety against progressive collapse should be used.

Place, publisher, year, edition, pages
2019. , p. 37
National Category
Construction Management
Identifiers
URN: urn:nbn:se:mdh:diva-44670OAI: oai:DiVA.org:mdh-44670DiVA, id: diva2:1331734
External cooperation
Subject / course
Building Engineering
Supervisors
Examiners
Available from: 2019-06-27 Created: 2019-06-27 Last updated: 2019-06-27Bibliographically approved

Open Access in DiVA

fulltext(1779 kB)32 downloads
File information
File name FULLTEXT01.pdfFile size 1779 kBChecksum SHA-512
1e6df5bf6457ec9496b93764c377ce965742c2b92511a482e9bc3d6669de11cc8da99e989bc44f387d4400ab1d2c2c90912ceb3d2aefc48f8e2bd0de06ce8b45
Type fulltextMimetype application/pdf

By organisation
School of Business, Society and Engineering
Construction Management

Search outside of DiVA

GoogleGoogle Scholar
Total: 32 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 147 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf