Evaluation of transcritical CO 2 heat pump system integrated with mechanical subcooling by utilizing energy, exergy and economic methodologies for residential heating
Tianjin Key Laboratory of Refrigeration Technology, Tianjin University of Commerce, Tianjin, China.
Tianjin Key Laboratory of Refrigeration Technology, Tianjin University of Commerce, Tianjin, China.
Tianjin Key Laboratory of Refrigeration Technology, Tianjin University of Commerce, Tianjin, China.
Tianjin Key Laboratory of Refrigeration Technology, Tianjin University of Commerce, Tianjin, China.
Show others and affiliations
2019 (English)In: Energy Conversion and Management, ISSN 0196-8904, E-ISSN 1879-2227, Vol. 192, p. 202-220Article in journal (Refereed) Published
Abstract [en]

A transcritical CO 2 heat pump (HP) system for residential space heating integrated with direct dedicated mechanical subcooling (DMS) is proposed, and mathematical models are developed to study the annual energetic and economic performances considering the influence of frosting. The operation characteristics by adopting different heating terminals used in five typical cities are also assessed. The results show a maximum coefficient of performance (COP) is achieved at the optimum discharge pressure and subcooling degree. The COP is promoted by 24.4% and the discharge pressure is decreased by 2.093 MPa at the ambient temperature of −10 °C and water supply/return temperature of 45/40 °C. The seasonal performance factor (SPF) is enhanced more noticeably for severe cold region. For the case of Harbin using floor-coil radiator (FCR) or normal fan-coil unit (N-FCU) as heating terminal, SPF is improved by 32.0%. The highest SPF is achieved when small temperature difference fan-coil unit (STD-FCU) is employed. The exergy efficiency can also be apparently improved, especially for the cities located in severe cold region and using FCR or N-FCU as heating terminal due to the reduction in throttling loss of CO 2 system. The purchased equipment cost and electricity cost of the CO 2 HP with DMS are both lower than those of traditional CO 2 heat pump system. The CO 2 HP DMS system using STD-FCU as heating terminal shows superior economical efficiency to traditional system, with levelized annual total cost reduced by 7.51–15.27%. 

Place, publisher, year, edition, pages
Elsevier Ltd , 2019. Vol. 192, p. 202-220
Keywords [en]
Annual energy efficiency, Dedicated mechanical subcooling, Economic evaluation, Heat pump, Residential heating, Transcritical CO 2
National Category
Energy Engineering Energy Systems
Identifiers
URN: urn:nbn:se:mdh:diva-43304DOI: 10.1016/j.enconman.2019.03.094ISI: 000471083500017Scopus ID: 2-s2.0-85064445209OAI: oai:DiVA.org:mdh-43304DiVA, id: diva2:1314597
Available from: 2019-05-09 Created: 2019-05-09 Last updated: 2019-06-27Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Li, Hailong

Search in DiVA

By author/editor
Li, Hailong
By organisation
Future Energy Center
In the same journal
Energy Conversion and Management
Energy EngineeringEnergy Systems

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 169 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf