https://www.mdu.se/

mdu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Posture Sensor as Feedback when Lifting Weights
Mälardalens högskola, Akademin för innovation, design och teknik, Inbyggda system. (Embedded Sensor Systems for Health (ESS-H))ORCID-id: 0000-0003-2686-4539
Mälardalens högskola, Akademin för innovation, design och teknik, Inbyggda system. (Embedded Sensor Systems for Health (ESS-H))ORCID-id: 0000-0002-7882-5438
Mälardalens högskola, Akademin för innovation, design och teknik, Inbyggda system. (Embedded Sensor Systems for Health (ESS-H))ORCID-id: 0000-0001-8704-402X
2015 (Engelska)Konferensbidrag, Poster (med eller utan abstract) (Refereegranskat)
Abstract [en]

Introduction

When lifting a package or during strength training, right posture of the back is important to avoid back pain. Different sensor solutions to measure posture of the back are presented in research articles and patents. The aim of this study was to investigate the possibility of using Lumo Lift as a device of giving feedback of good posture when lifting weights.

Method

Lumo Lift (Lumo Body Tech, Inc, USA) is an activity tracker aimed to for example guide the carrier to good posture. The small device is attached to the clothes using a magnetic clasp. It is calibrated to the user's good posture and vibrates when the posture is inaccurate. In this study the angle, in which the Lumo Lift is allowed to tilt before the device vibrates, was investigated. The device was placed at the top of a ruler and calibrated in upright position. Thereafter the ruler was tilted and the angle when the equipment vibrated was noted. Two different speeds of the tilts were performed. One speed simulating the normal speed of an inaccurate tilting torso when lifting weights. And one slow speed. Two Lumo Lifts were tilted 20 times forward and backwards, respectively.

Result

In normal speed the measured angle was between 6 and 25 degrees, when tilted forward, except two times when one of the devices gave no vibration during the whole tilt of 90 degrees. When tilted backwards the angle was between 8 and 32 degrees. During slow tilt the angle varied from 5 to 13 degrees forward and 4 to 13 degrees backwards.

Discussion and conclusion

Angle tilted before vibration is too large in normal tilting speed. This study indicates that Lumo Lift is not suitable of giving posture feedback during lifting in daily life.

Ort, förlag, år, upplaga, sidor
2015.
Nationell ämneskategori
Medicinteknik
Identifikatorer
URN: urn:nbn:se:mdh:diva-29463OAI: oai:DiVA.org:mdh-29463DiVA, id: diva2:868812
Konferens
4th International Conference on Ambulatory Monitoring of Physical Activity and Movement, ICAMPAM 2015, University of Limerick, Ireland, June 10-12.
Forskningsfinansiär
KK-stiftelsen, 20120275Tillgänglig från: 2015-11-11 Skapad: 2015-11-11 Senast uppdaterad: 2018-05-30Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

https://ulir.ul.ie/handle/10344/4487

Person

Hellstrom, Per Anders RickardÅkerberg, AnnaFolke, Mia

Sök vidare i DiVA

Av författaren/redaktören
Hellstrom, Per Anders RickardÅkerberg, AnnaFolke, Mia
Av organisationen
Inbyggda system
Medicinteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 964 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf