Technical issues related to the long-term monitoring of blood flow at different depths using LDF and PPG
Mälardalens högskola, Akademin för innovation, design och teknik. (IS)
Mälardalens högskola, Akademin för innovation, design och teknik. (IS)ORCID-id: 0000-0001-8704-402X
Linkoping Univ.
Mälardalens högskola, Akademin för innovation, design och teknik. (IS)ORCID-id: 0000-0003-1940-1747
2012 (engelsk)Inngår i: Physiological Measurement, ISSN 0967-3334, E-ISSN 1361-6579, Vol. 33, nr 6, s. 985-996Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The aim of this study was to evaluate an integrated probe using LDF and multiple PPG, for the long-term aspects of skin temperature and blood flow variations at different tissue depths, and especially to investigate whether the presence of the probe affects the temperature. Measurements of temperature and blood flow were performed over 60 min on the lower back of ten subjects, lying on a mattress. The surface temperature of the skin was also measured before and after the 60 min period, and repeated with three probe configurations with the probe switched on, turned off and in the absence of a probe. A general increase in the blood flow was found to occur during the 60 min interval at all depths reached by this probe, but with variations over time. No difference was found in temperatures recorded for the different probe configurations. According to our measurements, the presence of the probe does not affect the skin surface temperature at 60 min. Our investigation shows that skin temperature can be expected to increase and approach the body core temperature by just lying in supine position on the mattress. The increase in temperature and blood flow that is known to occur, possibly attributable to pressure-induced vasodilatation, must be taken into consideration when performing these kinds of measurements.

sted, utgiver, år, opplag, sider
2012. Vol. 33, nr 6, s. 985-996
HSV kategori
Identifikatorer
URN: urn:nbn:se:mdh:diva-16184DOI: 10.1088/0967-3334/33/6/985ISI: 000304562900008PubMedID: 22561159Scopus ID: 2-s2.0-84861165090OAI: oai:DiVA.org:mdh-16184DiVA, id: diva2:570846
Tilgjengelig fra: 2012-11-20 Laget: 2012-11-20 Sist oppdatert: 2019-06-18bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Personposter BETA

Folke, MiaLindén, Maria

Søk i DiVA

Av forfatter/redaktør
Hagblad, JimmieFolke, MiaLindén, Maria
Av organisasjonen
I samme tidsskrift
Physiological Measurement

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 74 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf