Köldbryggors inverkan på isoleringsegenskaper för sandwichelement: Anslutning mellan fönster och yttervägg
Mälardalen University, School of Sustainable Development of Society and Technology.
Mälardalen University, School of Sustainable Development of Society and Technology.
2010 (Swedish)Independent thesis Basic level (university diploma), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

I dagens läge har energifrågorna väckt ett stort intresse i samhället. Nu fokuseras det mer på att bygga energisnålare hus. En betydande faktor som påverkar energiförbrukningen i våra hus är köldbryggor. De uppstår då ett material med dålig värmeisolering bryter igenom ett material med bättre värmeisolering. Köldbryggor är nästan omöjligt att undvika, dock går alltid att reducera. I praktiken är det ofta inte möjligt att helt undvika köldbryggor, men det finns många olika möjligheter att minska köldbryggeffekten kraftigt. Detta eftersträvas för att uppnå lägre energikostnader eftersom köldbryggor kan medföra en betydande ökning av värmeförlusten. Avgränsningen för detta examensarbete framgår av titeln Köldbryggors inverkan på isoleringsegenskaper för sandwichelement, anslutning mellan fönster och yttervägg.

Den främsta metoden som används för att åstadkomma resultatet är PC-programmet HEAT2, men litteraturstudier har också använts. HEAT2 är ett tvådimensionellt värmeflödesprogram, som beräknar den värmemängd som leds genom konstruktionsdelen. Den bygger på att dela in byggnadsdelen i ett rutnät (mesh). Ju fler rutor den blir uppdelad i, desto noggrannare resultat, men beräkningen blir samtidigt mer tidskrävande att utföra.

En särskild analys gjordes med och utan den dränerande skyddsplasten i fönstrets överkant då materialet skär igenom värmeisoleringen vid betongklacken. Plasten har mångfaldigt högre värmekonduktivitet än värmeisoleringen, men den är bara 1 mm tjock. Beräkningsresultaten visar att skyddsplasten gav en betydande skillnad.

Abstract [en]

Currently, the energy issues brought a lot of interest in the community. Now is the focus more on building energy-efficient houses. A significant factor influencing energy consumption in our buildings is thermal bridges. They occur when a material with poor thermal insulation breaks through a material with better insulation. In practice it is often not possible to avoid thermal bridges completely, but there are many different options to reduce the thermal bridge effect significantly. This is desirable in order to achieve lower energy costs because thermal bridges can lead to a significant increase in the heat losses. The limitation of this degree project is evident from the title Thermal bridges impact on the insulation properties of sandwich panels, the connection between the windows and external walls

The primary means used to achieve the results is the HEAT2 PC-program, but literature studies were also used. HEAT2 is a two-dimensional heat flow program that calculates the amount of energy passed through the part of the construction. It is based on the allocation of the construction into a mesh, i.e. a grid. The more the mesh is divided into the more accurate the results, but the calculations are at the same time more time consuming to perform.

A separate analysis was done with and without the draining protective plastic in the window's top edge where the material is passing through the thermal insulation at the concrete heel. The plastic has many orders of magnitude higher thermal conductivity than the thermal insulation, but it is only 1 mm thick. The calculation results show that the plastic caused a significant difference.

Place, publisher, year, edition, pages
2010. , p. 40
Keywords [en]
Linear thermal bridges, sandwich panels, HEAT2, protective plastic, computer calculations, external walls, mesh
Keywords [sv]
Linjära köldbryggor, sandwichelement, HEAT2, skyddsplast, datorberäkningar, ytterväggar, rutnät
Identifiers
URN: urn:nbn:se:mdh:diva-11258OAI: oai:DiVA.org:mdh-11258DiVA, id: diva2:380197
Uppsok
Technology
Supervisors
Examiners
Available from: 2010-12-21 Created: 2010-12-20 Last updated: 2010-12-21Bibliographically approved

Open Access in DiVA

fulltext(1455 kB)677 downloads
File information
File name FULLTEXT01.pdfFile size 1455 kBChecksum SHA-512
2d5d3494faefb0c1b17c271f5f0bd74e5ac844033505b9f5decb3a216898abdef6cbc7d1bff894998d2ae2d9db0533a39968da8098bd26e2f017c442f4749e47
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Chamoun, RonneyHusseini, Salahadin
By organisation
School of Sustainable Development of Society and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 677 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 740 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf