Influence of residential ventilation on Radon mitigation with energy saving emphasis
Mälardalens högskola, Akademin för hållbar samhälls- och teknikutveckling.
2009 (engelsk)Inngår i:  PROCEEDINGS FROM SCIENTIFIC CONFERENCE ON GREEN ENERGY AND IT, 2009Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

There are many indoor pollutants in the residential buildings. High insulation and tightness in buildings in order to increase energy efficiency and to lower energy costs is led to the indoor air quality problems. To provide sufficient fresh air and to promote indoor air quality at acceptable level, it is needed to increase ventilation rate to overcome such pollutants.  

The aim of this paper is to study about energy efficient mechanical ventilation to overcome poor indoor air quality and energy consumption associated with radon ventilation.

 

Ventilation is a good method to dilute radon contaminant and maintain indoor air quality, but in the other hand ventilation is account for about 50 percent of energy use in residential buildings. Designing the required rate and location of ventilation systems and also choosing the best type of ventilation strategies can be provided both indoor air quality (IAQ) and building energy savings (BES).

 Computational fluid dynamics technique as a useful tool can be used to simulate and visualize radon treatment and mechanical ventilation rates for optimizing energy consumption and achieving to indoor air quality.

Results show that the exhaust fan installed in the middle another one in the left side have different impacts on distribution of radon contents in the room. Also when the rate of ventilation is changed from 7.5 l/s to 35 l/s the radon concentration will be decreased. By choosing the optimum features of ventilation system, energy saving can be obtained.

sted, utgiver, år, opplag, sider
2009.
Emneord [en]
Radon mitigation Ventilation Energy saving Residential building
HSV kategori
Forskningsprogram
energi- och miljöteknik
Identifikatorer
URN: urn:nbn:se:mdh:diva-7585ISBN: 978-91-9777493-4-3 (tryckt)OAI: oai:DiVA.org:mdh-7585DiVA, id: diva2:278677
Tilgjengelig fra: 2009-11-30 Laget: 2009-11-28 Sist oppdatert: 2009-11-30bibliografisk kontrollert

Open Access i DiVA

fulltekst(375 kB)901 nedlastinger
Filinformasjon
Fil FULLTEXT02.pdfFilstørrelse 375 kBChecksum SHA-512
dbdeb496ce6137324e461b95c748d9820d296f2efde83e1d296ce6375c9eb42aa4749fb77b5da74caaee36cc7761eb2d8b5527bbb0ab3525915ab48976eafcb3
Type fulltextMimetype application/pdf

Søk i DiVA

Av forfatter/redaktør
Akbari, Keramatollah
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 901 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

isbn
urn-nbn

Altmetric

isbn
urn-nbn
Totalt: 330 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf