Breast Tumor Detection Ability Using aPlanar 2.45 GHz System
Mälardalens högskola, Akademin för innovation, design och teknik. (Inteligent Sensor Systems)
L2S/Supélec/Université Paris-SUD 11. (Département de recherche en électromagnétisme)
L2S/Supélec/Université Paris-SUD 11. (Département de recherche en électromagnétisme)
L2S/Supélec/Université Paris-SUD 11. (Département de recherche en électromagnétisme)
(engelsk)Manuskript (Annet vitenskapelig)
Abstract [en]

This paper deals with the breast tumor detectionability of a planar microwave imaging system. Indeed, microwaveimaging seems to have a significant potential in such a biomedicalapplication. By means of a numerical model based upon electricfield volume integral equations, we investigate the influence ofseveral parameters, such as the respective sizes of the breastand the tumor, the operating frequency and the electromagneticproperties of the different media, on the detection ability. Thelatter is estimated by comparing the scattered fields observed inthe presence and in the absence of tumor and by accounting forthe signal to noise ratio available with the experimental setupdeveloped at the laboratory.

Emneord [en]
Breast Cancer Detection, Microwave Imaging
HSV kategori
Forskningsprogram
Elektronik
Identifikatorer
URN: urn:nbn:se:mdh:diva-5880OAI: oai:DiVA.org:mdh-5880DiVA, id: diva2:217293
Prosjekter
Microwaves in biomedicine
Merknad
Submitted to IEEE Transaction on Medical Imaging "©2009 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE." Tilgjengelig fra: 2009-05-13 Laget: 2009-05-13 Sist oppdatert: 2010-01-14bibliografisk kontrollert
Inngår i avhandling
1. CONTRIBUTION TO QUANTITATIVE MICROWAVE IMAGING TECHNIQUES FOR BIOMEDICAL APPLICATIONS
Åpne denne publikasjonen i ny fane eller vindu >>CONTRIBUTION TO QUANTITATIVE MICROWAVE IMAGING TECHNIQUES FOR BIOMEDICAL APPLICATIONS
2009 (engelsk)Doktoravhandling, med artikler (Annet vitenskapelig)
Abstract [en]

This dissertation presents a contribution to quantitative microwave imaging for breast tumor detection. The study made in the frame of a joint supervision Ph.D. thesis between University Paris-SUD 11 (France) and Mälardalen University (Sweden), has been conducted through two experimental microwave imaging setups, the existing 2.45 GHz planar camera (France) and the multi-frequency flexible robotic system, (Sweden), under development. In this context a 2D scalar flexible numerical tool based on a Newton-Kantorovich (NK) scheme, has been developed.

Quantitative microwave imaging is a three dimensional vectorial nonlinear inverse scattering problem, where the complex permittivity of an object is reconstructed from the measured scattered field, produced by the object. The NK scheme is used in order to deal with the nonlinearity and the ill-posed nature of this problem. A TM polarization and a two dimensional medium configuration have been considered in order to avoid its vectorial aspect. The solution is found iteratively by minimizing the square norm of the error with respect to the scattered field data. Consequently, the convergence of such iterative process requires, at least two conditions. First, an efficient calibration of the experimental system has to be associated to the minimization of model errors. Second, the mean square difference of the scattered field introduced by the presence of the tumor has to be large enough, according to the sensitivity of the imaging system.

The existing planar camera associated to a flexible 2D scalar NK code, are considered as an experimental platform for quantitative breast imaging. A preliminary numerical study shows that the multi-view planar system is quite efficient for realistic breast tumor phantoms, according to its characteristics (frequency, planar geometry and water as a coupling medium), as long as realistic noisy data are considered. Furthermore, a multi-incidence planar system, more appropriate in term of antenna-array arrangement, is proposed and its concept is numerically validated.

On the other hand, an experimental work which includes a new fluid-mixture for the realization of a narrow band cylindrical breast phantom, a deep investigation in the calibration process and model error minimization, is presented. This conducts to the first quantitative reconstruction of a realistic breast phantom by using multi-view data from the planar camera. Next, both the qualitative and quantitative reconstruction of 3D inclusions into the cylindrical breast phantom, by using data from all the retina, are shown and discussed. Finally, the extended work towards the flexible robotic system is presented.

sted, utgiver, år, opplag, sider
Västerås: Mälardalen University, 2009. s. 113
Serie
Mälardalen University Press Dissertations, ISSN 1651-4238 ; 73
Emneord
Quantitative Microwave Imaging. Inverse Problems, Nonliear Inverse Scattering, Diffraction Tomography, Breast Tumor Detection, Biomedical Imaging, Mammography, Calibration, Modeling, Planar 2.45 GHz Microwave Camera, Robot-based flexible multi-frequency data acquisition
HSV kategori
Forskningsprogram
Elektronik
Identifikatorer
urn:nbn:se:mdh:diva-5882 (URN)978-91-86135-27-0 (ISBN)
Disputas
2009-06-09, Lambda, Högskoleplan 1, Västerås, 09:30 (engelsk)
Opponent
Veileder
Prosjekter
Microwaves in biomedicine
Merknad
A dissertation prepared through an international convention for a joint supervision thesis with Université Paris-SUD 11, FranceTilgjengelig fra: 2009-05-14 Laget: 2009-05-13 Sist oppdatert: 2009-05-25bibliografisk kontrollert

Open Access i DiVA

fulltekst(339 kB)678 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 339 kBChecksum SHA-512
21485a98b664569b75ec93d8744154e9b1ea54780cea3701a791460c9f777f1940739cbf9a3f27743ac8ea25f63976e0cfb04fe36389a9d748b01c62fc6740b0
Type fulltextMimetype application/pdf

Søk i DiVA

Av forfatter/redaktør
Henriksson, Tommy
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 678 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 225 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf