https://www.mdu.se/

mdh.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Do ‘green’ data centres really have zero CO2 emissions?
Faculty of Maritime and Transportation, Ningbo University, Ningbo, 315211, China.
Centre for Strategic Energy and Resources, Singapore.
Mälardalens universitet, Akademin för ekonomi, samhälle och teknik, Framtidens energi.ORCID-id: 0000-0002-1351-9245
Mälardalens universitet, Akademin för ekonomi, samhälle och teknik, Framtidens energi. Wrocław University of Science and Technology, Wrocław, Poland.ORCID-id: 0000-0001-9576-7877
Vise andre og tillknytning
2022 (engelsk)Inngår i: Sustainable Energy Technologies and Assessments, ISSN 2213-1388, E-ISSN 2213-1396, Vol. 53, artikkel-id 102769Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The claim of a green data centre is generally made based on a net-zero CO2 emission through a ‘balance-sheet’ approach, which considers renewable electricity through on-site installation or purchase agreement as abatement measures against the use of fossil electricity from the electric grid on an annual basis. However, when the hourly dynamic fuel mix is accounted for in the assessment, the annual net-zero energy approach does not lead to a true carbon neutral data centre. In response, two approaches based on net-zero energy and net-zero CO2 emission respectively are proposed and investigated regarding the goal of net-zero CO2 emission. A data centre in Singapore with typical load profiles is used as a case study, different scenarios considering climate change and projected future energy are defined to examine the impacts of dynamic energy mix on the net CO2 emission of the data centre. The net-zero energy approach is found to result in significant amount of annual CO2 emissions. In comparison, the net-zero CO2 emission approach can assure a true net-zero CO2 emission, but this approach will require an increase of PV capacity by 20% and 60% as compared to the net-zero energy approach based on assessment for the year 2030 and 2050, respectively.

sted, utgiver, år, opplag, sider
Elsevier Ltd , 2022. Vol. 53, artikkel-id 102769
Emneord [en]
Dynamic energy mix, Green data centre, Hourly carbon intensity, Zero CO2 emission, Carbon, Climate change, Green computing, Balance sheet approach, Carbon intensity, CO 2 emission, Datacenter, Dynamic energy mixes, Energy approach, Green data centers, Renewable electricity, Carbon dioxide
HSV kategori
Identifikatorer
URN: urn:nbn:se:mdh:diva-60082DOI: 10.1016/j.seta.2022.102769ISI: 000895323800005Scopus ID: 2-s2.0-85138455426OAI: oai:DiVA.org:mdh-60082DiVA, id: diva2:1701208
Tilgjengelig fra: 2022-10-05 Laget: 2022-10-05 Sist oppdatert: 2023-09-13bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Campana, Pietro EliaJurasz, JakobLi, HailongYan, Jinyue

Søk i DiVA

Av forfatter/redaktør
Campana, Pietro EliaJurasz, JakobLi, HailongYan, Jinyue
Av organisasjonen
I samme tidsskrift
Sustainable Energy Technologies and Assessments

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 154 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf