https://www.mdu.se/

mdu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Cost-reliability analysis of hybrid pumped-battery storage for solar and wind energy integration in an island community
Univ Costa, Dept Civil & Environm, Calle 58 55-66, Barranquilla 080002, Atlantico, Colombia..ORCID-id: 0000-0002-6858-1855
Mälardalens universitet, Akademin för ekonomi, samhälle och teknik, Framtidens energi. AGH Univ Sci & Technol, Fac Management, Dept Engn Management, 30 Mickiewicza Ave, PL-30059 Krakow, Poland..ORCID-id: 0000-0001-9576-7877
Mostaganem Univ, Dept Elect Engn, BP188-227, Mostaganem 27000, Algeria..ORCID-id: 0000-0002-1301-807X
Univ Fed Rio Grande do Sul, Inst Pesquisas Hidraulicas, Porto Alegre, RS, Brazil..ORCID-id: 0000-0003-1507-9519
2021 (Engelska)Ingår i: Sustainable Energy Technologies and Assessments, ISSN 2213-1388, E-ISSN 2213-1396, Vol. 44, artikel-id 101062Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

This paper presents a mathematical model for estimating the optimal sizing and assessing a standalone hybrid power system's performance entirely based on variable renewable energy sources and coupled with a hybrid energy storage system. This study evaluates how different levels of the main components' capital cost and the loss of power supply probability would affect the cost of energy and the power system's optimal sizing. The case study selected for this study was Ometepe Island in Nicaragua, where the crater lake of an extinct volcano was considered a feasible upper reservoir of a pumped storage hydropower plant, reducing the investments associated with this component. The mathematical formulation considers energy storage losses and gains, and the Pareto efficient solutions of the multi-objective optimization model simultaneously increase reliability, reduce the cost of energy, and minimize curtailment energy. By employing time-series with an hourly resolution, the model allows assessing the impact of the interannual variability of renewable energy sources on the system's performance. As for the case study, the cost of energy obtained from the model results ranges between (sic)0.047/kWh and (sic)0.095/kWh, based on international reference values, and these values match the information available in the literature and other databases.

Ort, förlag, år, upplaga, sidor
ELSEVIER , 2021. Vol. 44, artikel-id 101062
Nyckelord [en]
Hybrid power systems, Multi-objective optimization, Hybrid energy storage, Reliability, Energy management strategy
Nationell ämneskategori
Energiteknik
Identifikatorer
URN: urn:nbn:se:mdh:diva-58631DOI: 10.1016/j.seta.2021.101062ISI: 000651430100056Scopus ID: 2-s2.0-85101276877OAI: oai:DiVA.org:mdh-58631DiVA, id: diva2:1665924
Tillgänglig från: 2022-06-08 Skapad: 2022-06-08 Senast uppdaterad: 2023-09-13Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Jurasz, Jakob

Sök vidare i DiVA

Av författaren/redaktören
Canales, Fausto A.Jurasz, JakobGuezgouz, MohammedBeluco, Alexandre
Av organisationen
Framtidens energi
I samma tidskrift
Sustainable Energy Technologies and Assessments
Energiteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 127 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf