https://www.mdu.se/

mdh.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Cost-reliability analysis of hybrid pumped-battery storage for solar and wind energy integration in an island community
Univ Costa, Dept Civil & Environm, Calle 58 55-66, Barranquilla 080002, Atlantico, Colombia..ORCID-id: 0000-0002-6858-1855
Mälardalens universitet, Akademin för ekonomi, samhälle och teknik, Framtidens energi. AGH Univ Sci & Technol, Fac Management, Dept Engn Management, 30 Mickiewicza Ave, PL-30059 Krakow, Poland..ORCID-id: 0000-0001-9576-7877
Mostaganem Univ, Dept Elect Engn, BP188-227, Mostaganem 27000, Algeria..ORCID-id: 0000-0002-1301-807X
Univ Fed Rio Grande do Sul, Inst Pesquisas Hidraulicas, Porto Alegre, RS, Brazil..ORCID-id: 0000-0003-1507-9519
2021 (engelsk)Inngår i: Sustainable Energy Technologies and Assessments, ISSN 2213-1388, E-ISSN 2213-1396, Vol. 44, artikkel-id 101062Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

This paper presents a mathematical model for estimating the optimal sizing and assessing a standalone hybrid power system's performance entirely based on variable renewable energy sources and coupled with a hybrid energy storage system. This study evaluates how different levels of the main components' capital cost and the loss of power supply probability would affect the cost of energy and the power system's optimal sizing. The case study selected for this study was Ometepe Island in Nicaragua, where the crater lake of an extinct volcano was considered a feasible upper reservoir of a pumped storage hydropower plant, reducing the investments associated with this component. The mathematical formulation considers energy storage losses and gains, and the Pareto efficient solutions of the multi-objective optimization model simultaneously increase reliability, reduce the cost of energy, and minimize curtailment energy. By employing time-series with an hourly resolution, the model allows assessing the impact of the interannual variability of renewable energy sources on the system's performance. As for the case study, the cost of energy obtained from the model results ranges between (sic)0.047/kWh and (sic)0.095/kWh, based on international reference values, and these values match the information available in the literature and other databases.

sted, utgiver, år, opplag, sider
ELSEVIER , 2021. Vol. 44, artikkel-id 101062
Emneord [en]
Hybrid power systems, Multi-objective optimization, Hybrid energy storage, Reliability, Energy management strategy
HSV kategori
Identifikatorer
URN: urn:nbn:se:mdh:diva-58631DOI: 10.1016/j.seta.2021.101062ISI: 000651430100056Scopus ID: 2-s2.0-85101276877OAI: oai:DiVA.org:mdh-58631DiVA, id: diva2:1665924
Tilgjengelig fra: 2022-06-08 Laget: 2022-06-08 Sist oppdatert: 2023-09-13bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Jurasz, Jakob

Søk i DiVA

Av forfatter/redaktør
Canales, Fausto A.Jurasz, JakobGuezgouz, MohammedBeluco, Alexandre
Av organisasjonen
I samme tidsskrift
Sustainable Energy Technologies and Assessments

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 119 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf