mdh.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Säkerhet mot fortskridande ras för prefabricerade elementväggar: UNDERSÖKNING AV FLERBOSTADSHUS
Mälardalens högskola, Akademin för ekonomi, samhälle och teknik.
2019 (svensk)Independent thesis Basic level (professional degree), 10 poäng / 15 hpOppgave
Abstract [en]

Progressive collapses may occur when a bearing wall is eliminated for various reasons. It can be a gas explosion or collision accident of a train or a vehicle, but also during renovation of a building component. After the wall has been eliminated, the building should be undamaged and not suffer a progressive collapse. Such an event can be avoided through a vertical link. The purpose of this study is to examine how secure today's vertical strap’sare against progressive collapse, and to find a solution for reduced risk of collapse Method: This study includes a literature review and a case study. The literature review was performed by a deepening of the existing literature that investigated the progressive collapse and the vertical drag strip. The studies found through the database Google school and Discovery. The case study was conducted in Kadesjös which is an engineering office where drawings and calculations were performed. Result: The result indicates that the vertical strap used today cannot withstand the design load if the entire wall (including the screw attachment) is eliminated. The threaded rod will then be pulled out of the floor and a progressive collapse occurs. By mounting a 70x70mm plate in the floor this can be prevented. Without the plate it takes only 58 kN to pull out the threaded rod from the floor, but with the plate the connection’s capacity is increased to 100 kN and then the anchorage pipe limits the capacity. Conclusion: The conclusion of this thesis is that a plate that increases the vertical strap’s capacity and thereby increases the safety against progressive collapse should be used.

sted, utgiver, år, opplag, sider
2019. , s. 37
HSV kategori
Identifikatorer
URN: urn:nbn:se:mdh:diva-44670OAI: oai:DiVA.org:mdh-44670DiVA, id: diva2:1331734
Eksternt samarbeid
Fag / kurs
Building Engineering
Veileder
Examiner
Tilgjengelig fra: 2019-06-27 Laget: 2019-06-27 Sist oppdatert: 2019-06-27bibliografisk kontrollert

Open Access i DiVA

fulltext(1779 kB)41 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 1779 kBChecksum SHA-512
1e6df5bf6457ec9496b93764c377ce965742c2b92511a482e9bc3d6669de11cc8da99e989bc44f387d4400ab1d2c2c90912ceb3d2aefc48f8e2bd0de06ce8b45
Type fulltextMimetype application/pdf

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 41 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 154 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf