Evaluation of transcritical CO 2 heat pump system integrated with mechanical subcooling by utilizing energy, exergy and economic methodologies for residential heating
Tianjin Key Laboratory of Refrigeration Technology, Tianjin University of Commerce, Tianjin, China.
Tianjin Key Laboratory of Refrigeration Technology, Tianjin University of Commerce, Tianjin, China.
Tianjin Key Laboratory of Refrigeration Technology, Tianjin University of Commerce, Tianjin, China.
Tianjin Key Laboratory of Refrigeration Technology, Tianjin University of Commerce, Tianjin, China.
Visa övriga samt affilieringar
2019 (Engelska)Ingår i: Energy Conversion and Management, ISSN 0196-8904, E-ISSN 1879-2227, Vol. 192, s. 202-220Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

A transcritical CO 2 heat pump (HP) system for residential space heating integrated with direct dedicated mechanical subcooling (DMS) is proposed, and mathematical models are developed to study the annual energetic and economic performances considering the influence of frosting. The operation characteristics by adopting different heating terminals used in five typical cities are also assessed. The results show a maximum coefficient of performance (COP) is achieved at the optimum discharge pressure and subcooling degree. The COP is promoted by 24.4% and the discharge pressure is decreased by 2.093 MPa at the ambient temperature of −10 °C and water supply/return temperature of 45/40 °C. The seasonal performance factor (SPF) is enhanced more noticeably for severe cold region. For the case of Harbin using floor-coil radiator (FCR) or normal fan-coil unit (N-FCU) as heating terminal, SPF is improved by 32.0%. The highest SPF is achieved when small temperature difference fan-coil unit (STD-FCU) is employed. The exergy efficiency can also be apparently improved, especially for the cities located in severe cold region and using FCR or N-FCU as heating terminal due to the reduction in throttling loss of CO 2 system. The purchased equipment cost and electricity cost of the CO 2 HP with DMS are both lower than those of traditional CO 2 heat pump system. The CO 2 HP DMS system using STD-FCU as heating terminal shows superior economical efficiency to traditional system, with levelized annual total cost reduced by 7.51–15.27%. 

Ort, förlag, år, upplaga, sidor
Elsevier Ltd , 2019. Vol. 192, s. 202-220
Nyckelord [en]
Annual energy efficiency, Dedicated mechanical subcooling, Economic evaluation, Heat pump, Residential heating, Transcritical CO 2
Nationell ämneskategori
Energiteknik Energisystem
Identifikatorer
URN: urn:nbn:se:mdh:diva-43304DOI: 10.1016/j.enconman.2019.03.094ISI: 000471083500017Scopus ID: 2-s2.0-85064445209OAI: oai:DiVA.org:mdh-43304DiVA, id: diva2:1314597
Tillgänglig från: 2019-05-09 Skapad: 2019-05-09 Senast uppdaterad: 2019-06-27Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Personposter BETA

Li, Hailong

Sök vidare i DiVA

Av författaren/redaktören
Li, Hailong
Av organisationen
Framtidens energi
I samma tidskrift
Energy Conversion and Management
EnergiteknikEnergisystem

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 24 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf