Evaluation of conservation voltage reduction - a comparison based method
Mälardalens högskola, Akademin för ekonomi, samhälle och teknik, Framtidens energi.ORCID-id: 0000-0002-8720-748X
Independent Insulation Group, Ludvika, Sweden.
DNV-GL Energy, Göteborg, Sweden.
2018 (Engelska)Ingår i: 2018 53rd International Universities Power Engineering Conference (UPEC), Proceedings, IEEE, 2018, s. 1-5, artikel-id 474Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

Conservation voltage reduction (CVR) is based onthe premise that conserving energy by reducing voltage levels of the electrical system will lead to reduced electrical energy consumption. In this work a comparison-based method has been applied for assessing CVR effects in a distribution grid. The reference voltage on the secondary side of the primary substation was manually altered according to a predefined schedule during 6 months, that is, perform CVR on a substation and apply “normal” voltage to the same substation with a 2-week interval between the changes. Measurements (1 second RMS-values for voltages, active powers and reactive powers) and analysis were made at the 11 kV side of a 130/11 kV transformer of a primary substation, on outgoing feeders and at the 400 V side of 11/0.4 kV distribution transformers downstream of the primary substation as well as on downstream single rural and industrial customers. Active power at different reference voltage levels versus 24 hours divided into 10 minute intervals for reoccurring days of the week were plotted and analysed.

This work confirms the difficulties in obtaining predictable loads over time and to accurately analyse the load composition on all grid levels. Each are needed in order to quantify the effects of CVR and by extension optimising the grid operations without violating the power quality.

Ort, förlag, år, upplaga, sidor
IEEE, 2018. s. 1-5, artikel-id 474
Nyckelord [en]
Conservation voltage reduction, substation, power quality
Nationell ämneskategori
Annan elektroteknik och elektronik
Identifikatorer
URN: urn:nbn:se:mdh:diva-41667DOI: 10.1109/UPEC.2018.8542053ISI: 000468972100179Scopus ID: 2-s2.0-85059933823ISBN: 978-1-5386-2910-9 (digital)OAI: oai:DiVA.org:mdh-41667DiVA, id: diva2:1271399
Konferens
53rd International Universities Power Engineering Conference (UPEC) 4-7 September 2018, Glasgow
Tillgänglig från: 2018-12-17 Skapad: 2018-12-17 Senast uppdaterad: 2019-06-25Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Foskolos, Georgios

Sök vidare i DiVA

Av författaren/redaktören
Foskolos, Georgios
Av organisationen
Framtidens energi
Annan elektroteknik och elektronik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetricpoäng

doi
isbn
urn-nbn
Totalt: 149 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf