mdh.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Heat losses and thermal performance of combined solar and pellet heating systems
Mälardalens högskola, Institutionen för samhällsteknik.
2004 (engelsk)Inngår i: Proceedings of EuroSun 2004 Conference, Freiburg, Germany, June 20-23 2004, 2004Konferansepaper, Publicerat paper (Annet vitenskapelig)
sted, utgiver, år, opplag, sider
2004.
HSV kategori
Identifikatorer
URN: urn:nbn:se:mdh:diva-4041ISBN: 3980965600 (tryckt)OAI: oai:DiVA.org:mdh-4041DiVA, id: diva2:120579
Konferanse
European Solar Conference (EuroSun 2004), EuroSun Conference 2004 Freiburg, Germany, 20–23 June 2004
Tilgjengelig fra: 2006-11-27 Laget: 2006-11-27 Sist oppdatert: 2015-07-28bibliografisk kontrollert
Inngår i avhandling
1. Combined solar and pellet heating systems: Study of energy use and CO-emissions
Åpne denne publikasjonen i ny fane eller vindu >>Combined solar and pellet heating systems: Study of energy use and CO-emissions
2006 (engelsk)Doktoravhandling, med artikler (Annet vitenskapelig)
Abstract [en]

In this study 4 solar and pellet heating systems have been studied with the help of annual dynamic simulations. Two of the systems comprised a pellet stove and two systems were solar combisystems; one with a store integrated pellet burner, the other with a separate pellet boiler.

The aim was to evaluate their thermal performance and their CO-emissions. The systems have been modelled based on lab measurements of the single system components. The used models allow a detailed study of the dynamic behaviour of the systems.

The stove systems have the least primary energy consumption provided the auxiliary electricity is taken into account with a conversion factor of 100%. If the auxiliary electricity is taken into account with a conversion of 40% and/or the systems are placed in the heated area the combisystems need less or a similar amount of primary energy.

Modulating combustion power reduces the number of starts and stops and for most pellet units this reduces the total CO emissions. The obtained annual CO emissions are higher than the values obtained from the standard test methods. It was shown that the average emissions under realistic annual conditions were greater than the limit values of two Eco-labels.

The system performance can be significantly improved by a proper control of the pellet heater and by sizing the pellet heater according to the size of the peak space heating demand.

Based on these findings from the simulations two prototypes of a combined solar and pellet heating system has been designed, built and tested; one for the lab and one that has been installed in a demonstration house. The system is very compact and is suitable for detached houses with no heating room or little space for a heating room.

sted, utgiver, år, opplag, sider
Institutionen för Samhällsteknik, 2006. s. 95
Serie
Mälardalen University Press Dissertations, ISSN 1651-4238 ; 36
Emneord
Solar heating, pellet heating
HSV kategori
Forskningsprogram
Energi- och miljöteknik
Identifikatorer
urn:nbn:se:mdh:diva-167 (URN)91-85485-30-6 (ISBN)
Disputas
2006-12-19, Gamma, Västerås, 09:30
Opponent
Veileder
Tilgjengelig fra: 2006-11-27 Laget: 2006-11-27

Open Access i DiVA

Fulltekst mangler i DiVA

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

isbn
urn-nbn

Altmetric

isbn
urn-nbn
Totalt: 106 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf