Energetic performance of transcritical CO2 refrigeration cycles with mechanical subcooling using zeotropic mixture as refrigerant
Tianjin University of Commerce, Tianjin, China.
Tianjin University of Commerce, Tianjin, China.
Mälardalens högskola, Akademin för ekonomi, samhälle och teknik, Framtidens energi. Tianjin University of Commerce, Tianjin, China.ORCID-id: 0000-0002-6279-4446
Tianjin University of Commerce, Tianjin, China.
Visa övriga samt affilieringar
2018 (Engelska)Ingår i: Energy, ISSN 0360-5442, E-ISSN 1873-6785, Vol. 150, s. 205-221Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Transcritical CO2 refrigeration cycle integrated with mechanical subcooling (MS) cycle operating with zeotropic mixture is proposed in this study, based on the concept of Lorenz cycle. An energetic model is developed and analyses are conducted in detail. A maximum overall coefficient of performance (COP) is achieved at the optimum discharge pressure and optimum subcooling degree. The maximum overall COP, optimum subcooling degree and discharge pressure are closely related to the temperature glide of the mixtures. The energy efficiency of the transcritical CO2 refrigeration cycle can be efficiently improved, and the high pressure can be reduced when mixtures with proper temperature glide are used as MS cycle refrigerant. Compared with pure R32, the overall COP is enhanced by 4.91%, and the discharge pressure decreases by 0.11 MPa at evaporation temperature of −5 °C and ambient temperature of 35 °C when R32/R1234ze(Z) (55/45) is employed as MS refrigerant. The mixtures with proper temperature glide are recommended. The thermal performance of the overall cycle can be enhanced more significantly for hot and warm climate regions, or relative low evaporation temperature applications, though a high subcooling degree is required to meet the optimum operation condition.

Ort, förlag, år, upplaga, sidor
Elsevier Ltd , 2018. Vol. 150, s. 205-221
Nationell ämneskategori
Energiteknik
Identifikatorer
URN: urn:nbn:se:mdh:diva-38847DOI: 10.1016/j.energy.2018.02.111ISI: 000431748400018Scopus ID: 2-s2.0-85042635481OAI: oai:DiVA.org:mdh-38847DiVA, id: diva2:1190651
Tillgänglig från: 2018-03-15 Skapad: 2018-03-15 Senast uppdaterad: 2018-05-31Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Personposter BETA

Li, Hailong

Sök vidare i DiVA

Av författaren/redaktören
Li, Hailong
Av organisationen
Framtidens energi
I samma tidskrift
Energy
Energiteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 32 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf