Optimization of floating PV systems: Case study for a shrimp farm in Thailand
Mälardalens högskola, Akademin för ekonomi, samhälle och teknik, Framtidens energi.
2017 (engelsk)Independent thesis Advanced level (degree of Master (Two Years)), 20 poäng / 30 hpOppgave
Abstract [en]

The use of solar photovoltaic (PV) systems have expanded rapidly the last decade and today’s market includes several different solar utilizations, where floating PV is one of them. Previous studies have shown how floating PV systems increase the PV efficiency and at the same time reduce the water evaporation. The purpose of this study is to evaluate and optimize energy solutions using floating PV systems for a shrimp farm cultivation in Thailand, where the technical, environmental and economic aspects will be included. The optimizations have been done in the open source model OptiCE, where genetic algorithm (AG) have been used to maximize the renewable reliability and minimize the Levelized Costs of Electricity (LCOE). In order to find the optimal renewable solution for the investigated shrimp farm, four scenarios have been compared considering different PV system combinations. The simulated results showed how the scenarios considering floating PV system generated a higher reliability than the scenarios considering ground-mounted PV system. The scenario considered tracking PV system increased the system´s renewable reliability compared to fixed PV system. However the shrimp farm is connected to the national electric grid or not will have a huge impact on the LCOE due to the low electric price and the implemented feed-in-tariff (FIT) program. The size of the installed PV capacity significantly affects the reliability results were the capacity of 200 kWp reaches a reliability of almost 100%. The optimal solution for the investigated shrimp farm to become independent is therefore to install a combined floating PV and battery storage system.

sted, utgiver, år, opplag, sider
2017. , s. 44
Emneord [en]
Shrimp farm cultivation, OptiCE, Renewable reliability, LCOE, Floating PV system, Tracking floating system
HSV kategori
Identifikatorer
URN: urn:nbn:se:mdh:diva-36015OAI: oai:DiVA.org:mdh-36015DiVA, id: diva2:1118654
Fag / kurs
Energy Engineering
Veileder
Examiner
Tilgjengelig fra: 2017-07-03 Laget: 2017-07-01 Sist oppdatert: 2017-07-03bibliografisk kontrollert

Open Access i DiVA

Optimization of floating PV systems: Case study for a shrimp farm in Thailand(1529 kB)2240 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 1529 kBChecksum SHA-512
eb02d041311ffc4e0e9e5702b7c9bc92296a63f07ba741bcef8ef792b8d4ff885429a4ac32adbd6cba10791f5a0c2318221c66733ce15bb784047c4e01c74ac9
Type fulltextMimetype application/pdf

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 2240 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 721 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf