SYSTEM IDENTIFICATION OF A WASTE-FIRED CFB BOILER: Using Principal Component Analysis (PCA) and Partial Least Squares Regression modeling (PLS-R)
Mälardalens högskola, Akademin för ekonomi, samhälle och teknik.
Mälardalens högskola, Akademin för ekonomi, samhälle och teknik.
2017 (Engelska)Självständigt arbete på grundnivå (kandidatexamen), 10 poäng / 15 hpStudentuppsats (Examensarbete)
Abstract [en]

Heat and electricity production along with waste management are two modern day challenges for society. One of the possible solution to both of them is the incineration of household waste to produce heat and electricity. Incineration is a waste-to-energy treatment process, which can reduce the need for landfills and save the use of more valuable fuels, thereby conserving natural resources. This report/paper investigates the performance and emissions of a municipal solid waste (MSW) fueled industrial boiler by performing a system identification analysis using Principle Component Analysis (PCA) and Partial Least Squares Regression (PLS-R) modeling. The boiler is located in Västerås, Sweden and has a maximum capacity of 167MW. It produces heat and electricity for the city of Västerås and is operated by Mälarenergi AB. A dataset containing 148 different boilers variables, measured with a one hour interval over 2 years, was used for the system identification analysis. The dataset was visually inspected to remove obvious outliers before beginning the analysis using a multivariate data analysis software called The Unscrambler X (Version 10.3, CAMO Software, Norway). Correlations found using PCA was taken in account during the PLSR modelling where models were created for one response each. Some variables had an unexpected impact on the models while others were fully logical regarding combustion theory. Results found during the system analysis process are regarded as reliable. Any errors may be due to outlier data points and model inadequacies.

Ort, förlag, år, upplaga, sidor
2017. , s. 58
Nyckelord [en]
Household Waste, Incineration, MWS, PCA, PLS-R, System identification, Waste Management
Nationell ämneskategori
Energisystem
Identifikatorer
URN: urn:nbn:se:mdh:diva-34979OAI: oai:DiVA.org:mdh-34979DiVA, id: diva2:1077816
Externt samarbete
Elena Tomas Aparicio, Mälarenergi AB
Ämne / kurs
Energiteknik
Presentation
2016-12-16, R2-205, Högskoleplan 1, Västerås, 10:30 (Engelska)
Handledare
Examinatorer
Tillgänglig från: 2017-03-17 Skapad: 2017-03-01 Senast uppdaterad: 2017-03-17Bibliografiskt granskad

Open Access i DiVA

fulltext(1783 kB)157 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 1783 kBChecksumma SHA-512
3ad1c505d1109e61f65cd7b1103973f2dfbd19f675c2251cfd3a3311c6dbe769dfe0236e16c1286e2c6c9013275ca167743baebea8ce65fbf5cbb1d7a5ca4db4
Typ fulltextMimetyp application/pdf

Sök vidare i DiVA

Av författaren/redaktören
Hassling, AndreasFlink, Simon
Av organisationen
Akademin för ekonomi, samhälle och teknik
Energisystem

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 157 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 537 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf