Dynamic performance of the standalone wind power driven heat pump
Mälardalens högskola, Akademin för ekonomi, samhälle och teknik, Framtidens energi. Ningbo RX New Materials Tch. Co. Ltd., China; KTH, Stockholm, Sweden. (Energy Technology)ORCID-id: 0000-0002-6279-4446
Mälardalens högskola, Akademin för ekonomi, samhälle och teknik, Framtidens energi. Ningbo RX New Materials Tch. Co. Ltd., China.ORCID-id: 0000-0002-1351-9245
Ningbo RX New Materials Tch. Co. Ltd., China; KTH, Stockholm, Sweden.
Visa övriga samt affilieringar
2016 (Engelska)Ingår i: Energy Procedia, ISSN 1876-6102, E-ISSN 1876-6102, Vol. 103, s. 40-45Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Reducing energy consumption and increasing use of renewable energy in the building sector is crucial to the mitigationof climate change. Wind power driven heat pumps have been considered as a sustainable measure to supply heat forthe detached houses, especially those that even don’t have access to the grid. This work is to investigate the dynamic performance of a heat pump system directly driven by a wind turbine. The heat demand of a detached single familyhouse was simulated in details. To handle the intermittent characteristic of wind power, an electric energy storage system was included. According to the simulations, the wind turbine itself cannot always satisfy the electricity demand of the heat pump, and a larger size of the energy storage system can reduce the probability of load loss. However, it is different from the energy storage system that increasing the capacity of wind turbines may increase the probability of load loss instead, due to the different start-up speed of wind turbines. In order to maximize the system benefit, the capacity of the wind turbine and the size of the energy storage system should be optimized simultaneously based on dynamic simulations.

Ort, förlag, år, upplaga, sidor
2016. Vol. 103, s. 40-45
Nationell ämneskategori
Energiteknik
Identifikatorer
URN: urn:nbn:se:mdh:diva-33719DOI: 10.1016/j.egypro.2016.11.246ISI: 000398028300007Scopus ID: 2-s2.0-85010867702OAI: oai:DiVA.org:mdh-33719DiVA, id: diva2:1048050
Konferens
Applied Energy Symposium and Forum, REM2016: Renewable Energy Integration with Mini/Microgrid, Apr19-21, 2016, Maldives
Tillgänglig från: 2016-11-20 Skapad: 2016-11-20 Senast uppdaterad: 2018-11-29Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Sök vidare i DiVA

Av författaren/redaktören
Li, HailongCampana, Pietro EliaYan, Jinyue
Av organisationen
Framtidens energi
I samma tidskrift
Energy Procedia
Energiteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 264 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf