Assessment of the optical interference in a PPG-LDF system used for estimation of tissue blood flow
Mälardalens högskola, Akademin för innovation, design och teknik. (ISS)
Mälardalens högskola, Akademin för innovation, design och teknik. (ISS)ORCID-id: 0000-0001-8704-402X
Linköpings Universitet, IMT.
Mälardalens högskola, Akademin för innovation, design och teknik. (ISS)ORCID-id: 0000-0003-1940-1747
2011 (Engelska)Ingår i: IFMBE PROCEEDINGS: 15th Nordic-Baltic Conference on Biomedical Engineering and Medical Physics, NBC 2011; Aalborg; 14 June 2011 through 17 June 2011 / [ed] Kim Dremstrup, 2011Konferensbidrag, Publicerat paper (Refereegranskat)
Ort, förlag, år, upplaga, sidor
2011.
Nationell ämneskategori
Medicinsk laboratorieteknik
Forskningsämne
elektronik
Identifikatorer
URN: urn:nbn:se:mdh:diva-12223DOI: 10.1007/978-3-642-21683-1_4ISI: 000308452500004Scopus ID: 2-s2.0-79959985250ISBN: 9783642216824 (tryckt)OAI: oai:DiVA.org:mdh-12223DiVA, id: diva2:415677
Tillgänglig från: 2011-05-09 Skapad: 2011-05-09 Senast uppdaterad: 2025-02-09Bibliografiskt granskad
Ingår i avhandling
1. Non-invasive techniques for assessment of peripheral blood flow at different vascular depths
Öppna denna publikation i ny flik eller fönster >>Non-invasive techniques for assessment of peripheral blood flow at different vascular depths
2011 (Engelska)Licentiatavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

Missing or reduced blood flow can lead to pressure ulcers. Monitoring blood flow in areas prone to pressure ulcer development would be a valuable tool for prevention of pressure ulcers.

PPG and LDF are both established non invasive optical techniques that can be used to estimate the changes in blood flow in different tissue volumes. The aim of this thesis was to combine the established techniques, LDF and PPG, into one flexible silicon probe intended for evaluation of peripheral blood flow in tissue volumes prone to pressure ulcer development. Further, a temperature sensor was integrated.

Two probe configurations combining LDF and PPG has been evaluated regarding the ability to separate between shallow, medium and deep blood flow variations, and skin temperature changes. Further, techniques to reduce or totally avoid interference between LDF and PPG have been investigated.

The probes can be used to discriminate between blood flows at different vascular depths. The vascular depths reached by the different channels correspond to the depths of interest when investigating pressure ulcer aetiology. The probe itself has shown not to affect the skin surface temperature, neither due to the silicon sheet or the light. The skin temperature can be expected to rise and approach the body core temperature by lying in supine position alone, which has to be taken into consideration when designing studies.

By switching between the different light sources, interference can be totally avoided. When rapid blood flow variations at several vascular depths are of interest to evaluate, a peripheral placement of the LDF-fibre and an increased illumination power of the PPG-LEDs might be used to minimize the interference between LDF and PPG.

Both probes have shown potential to be used for investigation of the processes in pressure ulcer development.

Ort, förlag, år, upplaga, sidor
Västerås: Mälardalen University, 2011
Serie
Mälardalen University Press Licentiate Theses, ISSN 1651-9256 ; 131
Forskningsämne
elektronik
Identifikatorer
urn:nbn:se:mdh:diva-12226 (URN)978-91-7485-014-7 (ISBN)
Presentation
2011-05-19, Pi, Högskoleplan 1, Västerås, 14:00 (Svenska)
Opponent
Handledare
Tillgänglig från: 2011-05-09 Skapad: 2011-05-09 Senast uppdaterad: 2011-05-12Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Folke, MiaLindén, Maria

Sök vidare i DiVA

Av författaren/redaktören
Hagblad, JimmieFolke, MiaLindén, Maria
Av organisationen
Akademin för innovation, design och teknik
Medicinsk laboratorieteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetricpoäng

doi
isbn
urn-nbn
Totalt: 224 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf