SMALL SCALE ENERGY CONVERSION OF PLASTIC WASTE: Identification of gasification process parameters through modelling in Aspen Plus
Mälardalens högskola, Akademin för ekonomi, samhälle och teknik.
Mälardalens högskola, Akademin för ekonomi, samhälle och teknik.
2020 (Engelska)Självständigt arbete på avancerad nivå (yrkesexamen), 20 poäng / 30 hpStudentuppsats (Examensarbete)
Abstract [en]

The present work investigates further development of a small-scale fixed bed batch operating gasification pilot system intended to be used as a waste-to-energy process to reduce littering of PET-bottles on Pemba Island in Tanzania. By developing a simplified gasification model and identifying the most important parameters to obtain a syngas with a lower heating value suitable for combustion and maximizing the overall efficiency and cold gas efficiency. By a literature study the most important parameters were identified along with how the methodology for developing the model and selection of modelling software. The model was developed as an equilibrium-based model in Aspen Plus representing the pilot system, the most important parameters was identified as equivalence ratio and temperature. Multiple scenarios, regarding sensitivity analysis of these parameters was conducted to determine how the outcome of the process was affected. The model was validated against a reference study and was proven to be accurate with small variations. High content of methane and carbon monoxide promoted the highest lower heating value which was at an equivalence ratio of 0.25 and a temperature of 450°C, which also indicated the highest overall efficiency. Increasing the temperature favoured the carbon monoxide content and the cold gas efficiency but indicated a decrease in lower heating value and overall efficiency. It was concluded that the optimal operational conditions were at an equivalence ratio at 0.25 and a temperature at 450°C. At these conditions, the formation of by-products from the gasification is higher than at higher equivalence ratios and temperature which needs to be further investigated through experimental work. It was also concluded that the system could benefit to operate in a semi- batch configuration with a higher equivalence ratio to utilize the excess heat from the process.

Ort, förlag, år, upplaga, sidor
2020.
Nationell ämneskategori
Naturvetenskap
Identifikatorer
URN: urn:nbn:se:mdh:diva-49162OAI: oai:DiVA.org:mdh-49162DiVA, id: diva2:1448124
Ämne / kurs
Energiteknik
Handledare
Examinatorer
Tillgänglig från: 2020-07-03 Skapad: 2020-06-26 Senast uppdaterad: 2020-07-03Bibliografiskt granskad

Open Access i DiVA

fulltext(2052 kB)2558 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 2052 kBChecksumma SHA-512
c7f085fcf86b06b9a87036f917a8168ea9117c0d8d9376f7e8d4050c5e5cef498e24fcb351c08d77ac4b164953f55e6896a468e443c5d25614ea166656249d38
Typ fulltextMimetyp application/pdf

Av organisationen
Akademin för ekonomi, samhälle och teknik
Naturvetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 2559 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 1298 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf