mdh.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Comparison of publicly available beat detection algorithms performanances on the ECGs obtained by a patch ECG device
Mälardalens högskola, Akademin för innovation, design och teknik, Inbyggda system.
Mälardalens högskola, Akademin för innovation, design och teknik, Inbyggda system.ORCID-id: 0000-0002-2457-3079
Mälardalens högskola, Akademin för innovation, design och teknik, Inbyggda system.ORCID-id: 0000-0003-1940-1747
Jolef Stefan Inst, Dept Inst Commun Syst, Ljubljana, Slovenia..
2019 (Engelska)Ingår i: 2019 42ND INTERNATIONAL CONVENTION ON INFORMATION AND COMMUNICATION TECHNOLOGY, ELECTRONICS AND MICROELECTRONICS (MIPRO) / [ed] Koricic, M Butkovic, Z Skala, K Car, Z CicinSain, M Babic, S Sruk, V Skvorc, D Ribaric, S Gros, S Vrdoljak, B Mauher, M Tijan, E Pale, P Huljenic, D Grbac, TG Janjic, M, IEEE , 2019, s. 275-278Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

Eight ECG beat detection algorithms, from the PhysioNet's WFDR and Cardiovascular Signal toolboxes, were tested on twenty measurements, obtained by the Savvy patch ECG device, for their accuracy in beat detection. On each subject, one measurement is obtained while sitting and one while running. Each measurement lasted from thirty seconds to one minute. The measurements obtained while running were more challenging for all the algorithms, as most of them almost perfectly detected all the beats on the measurements obtained in sitting position. However, when applied on the measurements obtained while running, all the algorithms have performed with decreased accuracy. Considering overall percentage of the faulty detected peaks, the four best algorithms were jqrs, from the Cardiovascular Signal Toolbox, and ecgpuwave, gqrs, and wqrs, from the WEDB Toolbox, with percentages of faulty detected beats 1.7, 2.3, 2.9, and 3, respectively.

Ort, förlag, år, upplaga, sidor
IEEE , 2019. s. 275-278
Nyckelord [en]
Patch ECG, R-peaks, heat detection, heart rate, telemonitoring, remote health monitoring
Nationell ämneskategori
Medicinteknik
Identifikatorer
URN: urn:nbn:se:mdh:diva-45375ISI: 000484544500052ISBN: 978-953-233-098-4 (tryckt)OAI: oai:DiVA.org:mdh-45375DiVA, id: diva2:1357333
Konferens
2019 42ND INTERNATIONAL CONVENTION ON INFORMATION AND COMMUNICATION TECHNOLOGY, ELECTRONICS AND MICROELECTRONICS (MIPRO)
Tillgänglig från: 2019-10-03 Skapad: 2019-10-03 Senast uppdaterad: 2019-10-03Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Personposter BETA

Tomasic, IvanPetrovic, NikolaLindén, Maria

Sök vidare i DiVA

Av författaren/redaktören
Tomasic, IvanPetrovic, NikolaLindén, Maria
Av organisationen
Inbyggda system
Medicinteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

isbn
urn-nbn

Altmetricpoäng

isbn
urn-nbn
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf