https://www.mdu.se/

mdu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Modelling the Quench Tower in Flue Gas Cleaning of a Waste Fueled Power Plant
Mälardalens högskola, Akademin för ekonomi, samhälle och teknik, Framtidens energi. Tianjin Univ Commerce, Key Lab Refrigerat Technol Tianjin, Peoples R China..
Mälardalens högskola, Akademin för ekonomi, samhälle och teknik, Framtidens energi. Tianjin Univ Commerce, Key Lab Refrigerat Technol Tianjin, Peoples R China..ORCID-id: 0000-0002-6279-4446
KTH Royal Inst Technol, Stockholm, Sweden..
Mälardalens högskola, Akademin för ekonomi, samhälle och teknik, Framtidens energi.ORCID-id: 0000-0002-3485-5440
Visa övriga samt affilieringar
2018 (Engelska)Ingår i: JOINT INTERNATIONAL CONFERENCE ON ENERGY, ECOLOGY AND ENVIRONMENT ICEEE 2018 AND ELECTRIC AND INTELLIGENT VEHICLES ICEIV 2018, DESTECH PUBLICATIONS, INC , 2018Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

To control the emission of pollutants in the flue gas, a separated flue gas quench was added after flue gas desulfurization and before flue gas condensation. A mathematic model was developed to simulate the heat and mass transfer in the flue gas quench. The model was validated through the comparison with measured data. Based on this model, the impacts of inlet flue gas condition and injected recycling water flow rate on the water consumption of the quench and the temperature of exit flue gas (FG) were studied. The results show that the temperature of exit FG and water consumption increased with the increase of flow rate and moisture content of FG. The temperature of exit FG increased and the water consumption decreased with the increase of droplet water diameter. The temperature of exit FG decreased and the water consumption increased with the increase of water flow rate. In order to cooled and humidified the flue gas sufficiently, the droplet diameter should be limited to 1.2 mm and the water to FG flow rate ratio (L/G) higher than 2.

Ort, förlag, år, upplaga, sidor
DESTECH PUBLICATIONS, INC , 2018.
Serie
DEStech Transactions on Environment Energy and Earth Sciences, ISSN 2475-8833
Nyckelord [en]
flue gas, quench, mathematic model, temperature of exit FG, water consumption
Nationell ämneskategori
Energiteknik
Identifikatorer
URN: urn:nbn:se:mdh:diva-43986ISI: 000468631900126ISBN: 978-1-60595-590-2 (tryckt)OAI: oai:DiVA.org:mdh-43986DiVA, id: diva2:1323616
Konferens
International Conference on Energy, Ecology and Environment (ICEEE) / International Conference on Electric and Intelligent Vehicles (ICEIV), NOV 21-25, 2018, Swinburne Univ Technol, Melbourne, AUSTRALIA
Tillgänglig från: 2019-06-12 Skapad: 2019-06-12 Senast uppdaterad: 2019-06-12Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Person

Li, HailongThorin, EvaSchwede, Sebastian

Sök vidare i DiVA

Av författaren/redaktören
Wang, BinLi, HailongThorin, EvaSchwede, Sebastian
Av organisationen
Framtidens energi
Energiteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

isbn
urn-nbn

Altmetricpoäng

isbn
urn-nbn
Totalt: 59 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf