Experimental investigation on the effect of heat sink temperature on operational characteristics of a new-type loop heat pipe
Tianjin Key Laboratory of Refrigeration technology, Tianjin University of Commerce, Tianjin 300134, China.
Tianjin Key Laboratory of Refrigeration technology, Tianjin University of Commerce, Tianjin 300134, China.
Mälardalens högskola, Akademin för ekonomi, samhälle och teknik, Framtidens energi. Tianjin Key Laboratory of Refrigeration technology, Tianjin University of Commerce, Tianjin 300134, China.ORCID-id: 0000-0002-6279-4446
Tianjin Key Laboratory of Refrigeration technology, Tianjin University of Commerce, Tianjin 300134, China.
Visa övriga samt affilieringar
2019 (Engelska)Ingår i: Energy Procedia, Elsevier Ltd , 2019, Vol. 158, s. 2423-2429Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

With the development of the miniaturization and the high integration of electronic chip, the thermal management of the high power electronic becomes a major challenge. In this paper the influence of heat sink temperature on operational characteristics was comprehensively conducted and the 35% of charging ratio was selected through the experiment study. To evaluate the LHP system, temperatures, start-up time, thermal resistance, and evaporator heat transfer coefficient were selected as performance indicators. The result showed that, there existed an optimal heat sink temperature (18 o C) to obtain the lowest evaporator bottom temperature (77 o C), the shortest start-up time (1000s), the smallest thermal resistance (0.29k/W), and the highest evaporator heat transfer coefficient (3.110 4 W/(m 2 ·k)). The temperature range to keep a high performance of LHP system was 14-20 o C. The conclusion obtained through the experiment can provide the reference of design the cooling system when the LHP system applied into the electric cooling.

Ort, förlag, år, upplaga, sidor
Elsevier Ltd , 2019. Vol. 158, s. 2423-2429
Nyckelord [en]
Heat sink temperature, Loop heat pipe, Operational characteristics, Pressure head of evaporation
Nationell ämneskategori
Annan teknik
Identifikatorer
URN: urn:nbn:se:mdh:diva-43141DOI: 10.1016/j.egypro.2019.01.298ISI: 000471031702120Scopus ID: 2-s2.0-85063900961OAI: oai:DiVA.org:mdh-43141DiVA, id: diva2:1305764
Konferens
10th International Conference on Applied Energy (ICAE2018), 22-25 August 2018, Hong Kong, China
Tillgänglig från: 2019-04-18 Skapad: 2019-04-18 Senast uppdaterad: 2019-07-11Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Li, Hailong

Sök vidare i DiVA

Av författaren/redaktören
Li, Hailong
Av organisationen
Framtidens energi
Annan teknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 69 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf