Potential for low temperature district heating system: Integrating 4th generation district heating system with existing technology
Mälardalens högskola, Akademin för ekonomi, samhälle och teknik.
2017 (Engelska)Självständigt arbete på avancerad nivå (masterexamen), 20 poäng / 30 hpStudentuppsats (Examensarbete)
Abstract [en]

This project presents a feasibility study and an investigation of the potential for low temperature district heating system in Västerås. The investigation treats integrations possibilities for 4GDH (4th Generation District Heating) in Kungsängens area in Västerås, which is undergoing a large-scale building-up and construction.  The study is conducted for the company Mälarenergi AB. The advantages of 4GDH technology are identified and analyzed, where energy effectiveness and economic benefits aspects were concluded. Problems with existing technology and higher cooling demand expectations drive 4GDH to be an interesting and necessary technology in the future. Four Different integration solutions between old and new networks are presented, analyzed and discussed. Quantitative analysis conducted where initial cost for the four technical solutions were estimated and compared. The results show that low temperature district heating could lead to reduction in the initial cost for the network by using PEX instead of steel as pipe material. The results show also that one solution using heat exchanger as exchange stations has the lowest cost between the four solutions. The results show that the cost for the retention flow that is linked with 4GDH stands for 20%-30% of the total cost. The importance of the retention flow pipe is investigated using two physical models in OpenModelica and Excel, where simulations were conducted. It is concluded that it is possible to provide Kungsängen area with low temperature district heating without having the retention flow pipe. Three parameters were identified to be critical which are, geographical placement of the consumers, pattern variation for the heat demand and heat systems installed inside consumer’s buildings. The results show also that it might be critical to have a variate and optimized supply temperature for the area, depending on the demand. The simulations of a fictive area that could present a future heat demand for Kungsängen area shows that a temperature of 55°C is satisfying during winter season where the demand is high and a temperature between 60-65°C must be available during spring/autumn seasons and specially during summer. The variation depends directly on the temperature drop through the supply pipes to the consumers. The temperature drop is directly linked with water velocity inside the pipes. The losses increase during summer nights when the heat demand is low which lead to low water velocities. 

Ort, förlag, år, upplaga, sidor
2017. , s. 66
Nyckelord [en]
Model, OpenModelica, retention flow, 4GDH, DHC, district cooling, combined heat and power
Nyckelord [sv]
Lågtempererad fjärrvärme, fjärde generationen fjärrvärme, modellering, simulering, fjärrkyla, varmhållning
Nationell ämneskategori
Energisystem
Identifikatorer
URN: urn:nbn:se:mdh:diva-35816OAI: oai:DiVA.org:mdh-35816DiVA, id: diva2:1110664
Externt samarbete
Mälarenergi AB
Ämne / kurs
Energiteknik
Handledare
Examinatorer
Tillgänglig från: 2017-06-27 Skapad: 2017-06-16 Senast uppdaterad: 2017-06-27Bibliografiskt granskad

Open Access i DiVA

fulltext(2202 kB)599 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 2202 kBChecksumma SHA-512
a05117b2cc16c331601d82d5c5fc729ea15e8ae96ceb7e156d19f04b90693f48f70052c28f31f02c2ba8920212ab93ede0ae145efe8464af420f0e0c1d1ce6f8
Typ fulltextMimetyp application/pdf

Av organisationen
Akademin för ekonomi, samhälle och teknik
Energisystem

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 599 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 783 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf