mdh.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
An Intelligent Healthcare Service to Monitor Vital Signs in Daily Life – A Case Study on Health-IoT
Mälardalens högskola, Akademin för innovation, design och teknik, Inbyggda system.ORCID-id: 0000-0003-3802-4721
2017 (Engelska)Ingår i: International Journal of Engineering Research and Applications, ISSN 2248-9622, E-ISSN 2248-9622, Vol. 7, nr 3, s. 43-55Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Vital signs monitoring for elderly in daily life environment is a promising concept that efficiently can provide medical services to people at home. However, make the system self-served and functioning as personalized provision makes the challenge even larger. This paper presents a case study on a Health-IoT system where an intelligent healthcare service is developed to monitor vital signs in daily life. Here, a generic Health-IoT framework with a Clinical Decision Support System (CDSS) is presented. The generic framework is mainly focused on the supporting sensors, communication media, secure and safe data communication, cloud-based storage, and remote accesses of the data. The CDSS is used to provide a personalized report on persons’ health condition based on daily basis observation on vital signs. Six participants, from Spain (n=3) and Slovenia (n=3) have been using the proposed healthcare system for eight weeks (e.g. 300+ health measurements) in their home environments to monitor their health. The sensitivity, specificity and overall accuracy of the DSS’s classification are achieved as 90%, 97% and 96% respectively while k=2 i.e., top 2 most similar retrieved cases are considered. The initial user evaluation result demonstrates the feasibility and performance of the implemented system through the proposed framework.

Ort, förlag, år, upplaga, sidor
Sweden, 2017. Vol. 7, nr 3, s. 43-55
Nationell ämneskategori
Datorsystem
Identifikatorer
URN: urn:nbn:se:mdh:diva-35485DOI: 10.9790/9622-0703024345OAI: oai:DiVA.org:mdh-35485DiVA, id: diva2:1104176
Projekt
ESS-H - Embedded Sensor Systems for Health Research Profileecare@homeTillgänglig från: 2017-05-31 Skapad: 2017-05-31 Senast uppdaterad: 2017-11-29Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Personposter BETA

Ahmed, Mobyen Uddin

Sök vidare i DiVA

Av författaren/redaktören
Ahmed, Mobyen Uddin
Av organisationen
Inbyggda system
I samma tidskrift
International Journal of Engineering Research and Applications
Datorsystem

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 131 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf