Fire suppression and structure protection for cargo train tunnels: Macadam and HotFoam
Mälardalens högskola, Akademin för ekonomi, samhälle och teknik. SP Brandteknik. (MERO)ORCID-id: 0000-0001-6758-6067
2008 (engelsk)Konferansepaper, Publicerat paper (Annet vitenskapelig)
Abstract [en]

The increasing heavy goods transports and potential of transporting goods on rail has put the focus on the fire safety of rail tunnels for cargo trains. In the paper two different aspects of fire behaviour and fire safety in cargo rail tunnels are presented: the effect of the use of macadam on the burning rate of liquid fuels and the possibility of extinguishing simulated cargo trains with foam systems. Two different tests series were performed. One test series with different depth of liquid fuel (heptane and diesel) in a pool with macadam showed that the macadam had a significant influence on the burning rate of the fuel. In a second test series a High Expansion foam system (HotFoam®) was tested in tunnel fire scenarios. Four different principle fire test scenarios were used in the test series in the tunnel section built in the fire hall of SP Fire Technology: hidden fire inside a locomotive mock-up, wood pallets placed on a simulated goods wagon, pool fire placed on a simulated goods wagon, and pool fire placed under a simulated goods wagon. Different types of fuels were used: diesel, heptane, E-85, acetone, and wood pallets. The Svenska Skum HotFoam fire extinguishing system was started with a pre-defined delay after alarm from the installed detection system and was able to extinguish all reported scenarios. Easiest to extinguish (shortest time between foam production and extinguishment) were the heptane fires, both on and below the simulated goods wagon. Most difficult to extinguish (with the same nominal filling rate of foam) was Test 7 with E-85.

sted, utgiver, år, opplag, sider
2008. s. 217-228
HSV kategori
Forskningsprogram
energi- och miljöteknik
Identifikatorer
URN: urn:nbn:se:mdh:diva-22794OAI: oai:DiVA.org:mdh-22794DiVA, id: diva2:664313
Konferanse
3rd International Symposium on Safety and Security in Tunnels (ISTSS 2008), Stockholm, Sweden, 12-14 March, 2008
Tilgjengelig fra: 2013-11-14 Laget: 2013-11-14 Sist oppdatert: 2019-12-12bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Person

Lönnermark, Anders

Søk i DiVA

Av forfatter/redaktør
Lönnermark, AndersKristensson, Peter
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric

urn-nbn
Totalt: 300 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf