Estimating the amount of water required to extinguish wildfires under different conditions and in various fuel types
Mälardalens högskola, Akademin för ekonomi, samhälle och teknik. (MERO)ORCID-id: 0000-0002-8326-2860
2012 (engelsk)Inngår i: International journal of wildland fire, ISSN 1049-8001, E-ISSN 1448-5516, Vol. 21, nr 5, s. 525-536Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

In wildland fires where water is used as the primary extinguishing agent, one of the issues of wildfire suppression is estimating how much water is required to extinguish a certain section of the fire. In order to use easily distinguished and available indicators, the flame length and the area of the active combustion zone were chosen as suitable for the modelling of extinguishing requirements. Using Byram's and Thomas' equations, the heat release rate per unit length of fire front was calculated for low-intensity surface fires, fires with higher wind conditions, fires in steep terrain and high-intensity crown fires. Based on the heat release rate per unit length of fire front, the critical water flow rate was calculated for the various cases. Further, the required amount of water for a specific active combustion zone area was calculated for various fuel models. Finally, the results for low-intensity surface fires were validated against fire experiments. The calculated volumes of water can be used both during the preparatory planning for incidents as well as during firefighting operations.

sted, utgiver, år, opplag, sider
2012. Vol. 21, nr 5, s. 525-536
Emneord [en]
active combustion zone, critical water application rate, fire point theory, flame length, suppression
HSV kategori
Forskningsprogram
energi- och miljöteknik
Identifikatorer
URN: urn:nbn:se:mdh:diva-17793DOI: 10.1071/WF11022ISI: 000307175200006Scopus ID: 2-s2.0-84864925492OAI: oai:DiVA.org:mdh-17793DiVA, id: diva2:588138
Tilgjengelig fra: 2013-01-15 Laget: 2013-01-15 Sist oppdatert: 2017-12-06bibliografisk kontrollert

Open Access i DiVA

fulltext(1041 kB)3463 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 1041 kBChecksum SHA-512
4c22683d6c445da7f2d626d89490069bca58b8ee7e4bc9f8b95121751acc0d864471bad036aedccf6e265f5846fca80ed1ef84939cca438d8a4a48de58e3036f
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekstScopus

Personposter BETA

Hansen, Rickard

Søk i DiVA

Av forfatter/redaktør
Hansen, Rickard
Av organisasjonen
I samme tidsskrift
International journal of wildland fire

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 3463 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 286 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf