mdh.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Optimal hybrid pumped hydro-battery storage scheme for off-grid renewable energy systems
Department of Electrical Engineering, Mostaganem University, Mostaganem, Algeria.
Mälardalens högskola, Akademin för ekonomi, samhälle och teknik, Framtidens energi. Faculty of Management, Department of Engineering Management, AGH University.,Cracow, Poland.
Department of Electrical Engineering, Mostaganem University, Mostaganem, Algeria.
School of Mechanical Engineering, Shanghai Jiao Tong University, China.
Vise andre og tillknytning
2019 (engelsk)Inngår i: Energy Conversion and Management, ISSN 0196-8904, E-ISSN 1879-2227, Vol. 199, artikkel-id 112046Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The development of energy storage systems paves the way towards a high integration of renewable energy sources in the electricity generation sector. Considering above, this paper introduces a new energy management strategy to efficiently coordinate a hybrid energy storage system based on pumped hydro storage (long term bulk storage) with batteries (short term, more flexible). For the purpose of this analysis, hourly time series of irradiation, wind speed, temperature and real measured load (characteristic for farmstead) covering one year were gathered for the selected site in Algeria. The optimal size of the system is determined based on a multi-objective optimization using a grey wolf optimizer implemented in MATLAB software. The results indicate that the hybrid storage system enables achieving higher reliability at lower cost in comparison to a system with single storage technology. The use of hybrid storage also reduces the curtailment of renewable generation. Further findings reveal that the cost of an optimal energy supply system with 97.5% reliability is 0.162 €/kWh, 0.207 €/kWh and 1.462 €/kWh for hybrid storage, battery and pumped storage, respectively. However, sensitivity analysis shows that the optimal hybrid storage configuration is less resilient when changes in irradiation/temperature/load are considered. This indicates that special actions (upscale of installed power) must be undertaken to avoid lower performance of hybrid storage systems. In summary, the hybrid storage system seems to be better sized for consideration in optimized solar/wind conditions, but by avoiding oversizing they are less resilient to future potential changes in renewable energy availability.

sted, utgiver, år, opplag, sider
Elsevier Ltd , 2019. Vol. 199, artikkel-id 112046
Emneord [en]
Battery, Energy management strategy, Hybrid storage, Optimization, Pumped-storage hydro, Renewable energy sources
HSV kategori
Identifikatorer
URN: urn:nbn:se:mdh:diva-45315DOI: 10.1016/j.enconman.2019.112046ISI: 000494884000078Scopus ID: 2-s2.0-85072275158OAI: oai:DiVA.org:mdh-45315DiVA, id: diva2:1355059
Tilgjengelig fra: 2019-09-26 Laget: 2019-09-26 Sist oppdatert: 2019-12-02bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Personposter BETA

Jurasz, Jakob

Søk i DiVA

Av forfatter/redaktør
Jurasz, Jakob
Av organisasjonen
I samme tidsskrift
Energy Conversion and Management

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 25 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf