Feasibility of using thermal inertia to shift the peak energy demand of buildings
Mälardalens högskola, Akademin för ekonomi, samhälle och teknik, Framtidens energi. Tianjin University of Commerce, Key Laboratory China of Refrigeration Technology of Tianjin, Tianjin, China.
Mälardalens högskola, Akademin för ekonomi, samhälle och teknik, Framtidens energi. Tianjin University of Commerce, Key Laboratory China of Refrigeration Technology of Tianjin, 300134, China.ORCID-id: 0000-0002-6279-4446
Tianjin University of Commerce, Key Laboratory China of Refrigeration Technology of Tianjin, China.
Tianjin University of Commerce, Key Laboratory China of Refrigeration Technology of Tianjin, China.
Vise andre og tillknytning
2018 (engelsk)Inngår i: International Heat Transfer Conference, Begell House Inc. , 2018, s. 4419-4424Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

Peak load introduces stress to the grid as supplied electricity is inadequate during peak demand period. In order to relieve the stress of grid and ensure the electricity supply, peak load shifting is an effective option. Buildings are consuming a huge amount of energy for space heating, ventilation and cooling. Using building thermal inertia to shift peak load has attracted more and more attention. By using thermal inertia, heat supplied during off-peak periods can be stored in the construction materials, and used in peak demand hours. However, peak shaving shall not sacrifice the indoor thermal comfort. The objective of this work is to investigate the impact of demand shifting by using thermal inertia on the indoor temperature. In order to understand how the demand shifting impacts the thermal comfort. A CFD model is developed to simulate an office room in winter time. Three cases that represent different shifting strategies are studied. According the results, when increasing the heating temperature, using thermal inertia of buildings can shift peak load, guarantee indoor thermal comfort and save energy. © 2018 International Heat Transfer Conference. All rights reserved.

sted, utgiver, år, opplag, sider
Begell House Inc. , 2018. s. 4419-4424
Emneord [en]
Energy conversion and storage, Numerical simulation and super-computing, Peak load shifting, Thermal comfort, Thermal inertia, Thermal storage
HSV kategori
Identifikatorer
URN: urn:nbn:se:mdh:diva-44885Scopus ID: 2-s2.0-85068328480OAI: oai:DiVA.org:mdh-44885DiVA, id: diva2:1336987
Konferanse
16th International Heat Transfer Conference, IHTC 2018, 10 August 2018 through 15 August 2018
Merknad

Conference code: 148757; Export Date: 11 July 2019; Conference Paper; Correspondence Address: Li, H.; Tianjin University of Commerce, Key Laboratory China of Refrigeration Technology of TianjinChina; email: hailongli@mdh.se

Tilgjengelig fra: 2019-07-11 Laget: 2019-07-11 Sist oppdatert: 2019-07-11bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Scopus

Personposter BETA

Chen, ChangLi, Hailong

Søk i DiVA

Av forfatter/redaktør
Chen, ChangLi, Hailong
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric

urn-nbn
Totalt: 15 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf