Photovoltaic/battery system sizing for rural electrification in Bolivia: Considering the suppressed demand effect
Department of Chemical Engineering, Applied Electrochemistry, KTH Royal Institute of Technology, Stockholm, Sweden.
Division of Safety and Transport/Electronics, RISE, Research Institutes of Sweden, Borås, Sweden.
Mälardalens högskola, Akademin för ekonomi, samhälle och teknik, Framtidens energi. Department of Chemical Engineering, Applied Electrochemistry, KTH Royal Institute of Technology, Stockholm, Sweden.ORCID-id: 0000-0002-1351-9245
Department of Chemical Engineering, Applied Electrochemistry, KTH Royal Institute of Technology, Stockholm, Sweden.
Vise andre og tillknytning
2019 (engelsk)Inngår i: Applied Energy, ISSN 0306-2619, E-ISSN 1872-9118, Vol. 235, s. 519-528Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Rural electrification programs usually do not consider the impact that the increment of demand has on the reliability of off-grid photovoltaic (PV)/battery systems. Based on meteorological data and electricity consumption profiles from the highlands of Bolivian Altiplano, this paper presents a modelling and simulation framework for analysing the performance and reliability of such systems. Reliability, as loss of power supply probability (LPSP), and cost were calculated using simulated PV power output and battery state of charge profiles. The effect of increasing the suppressed demand (SD) by 20% and 50% was studied to determine how reliable and resilient the system designs are. Simulations were performed for three rural application scenarios: a household, a school, and a health centre. Results for the household and school scenarios indicate that, to overcome the SD effect, it is more cost-effective to increase the PV power rather than to increase the battery capacity. However, with an increased PV-size, the battery ageing rate would be higher since the cycles are performed at high state of charge (SOC). For the health centre application, on the other hand, an increase in battery capacity prevents the risk of electricity blackouts while increasing the energy reliability of the system. These results provide important insights for the application design of off-grid PV-battery systems in rural electrification projects, enabling a more efficient and reliable source of electricity.

sted, utgiver, år, opplag, sider
Elsevier Ltd , 2019. Vol. 235, s. 519-528
HSV kategori
Identifikatorer
URN: urn:nbn:se:mdh:diva-42422DOI: 10.1016/j.apenergy.2018.10.084ISI: 000458942800043Scopus ID: 2-s2.0-85056217184OAI: oai:DiVA.org:mdh-42422DiVA, id: diva2:1282660
Tilgjengelig fra: 2019-01-25 Laget: 2019-01-25 Sist oppdatert: 2019-03-14bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Personposter BETA

Campana, Pietro Elia

Søk i DiVA

Av forfatter/redaktør
Campana, Pietro Elia
Av organisasjonen
I samme tidsskrift
Applied Energy

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 28 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf