https://www.mdu.se/

mdu.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
A Novel Fiducial Point Extraction Algorithm to Detect C and D Points from the Acceleration Photoplethysmogram (CnD)
Mälardalen University, School of Innovation, Design and Engineering, Embedded Systems.ORCID iD: 0000-0003-4841-2488
Mälardalen University, School of Innovation, Design and Engineering, Embedded Systems.ORCID iD: 0000-0001-6640-1868
Mälardalen University, School of Innovation, Design and Engineering, Embedded Systems.ORCID iD: 0000-0001-8704-402X
Mälardalen University, School of Innovation, Design and Engineering, Embedded Systems.ORCID iD: 0000-0003-1940-1747
Show others and affiliations
2023 (English)In: Electronics, E-ISSN 2079-9292, Vol. 12, no 5, article id 1174Article in journal (Refereed) Published
Abstract [en]

The extraction of relevant features from the photoplethysmography signal for estimating certain physiological parameters is a challenging task. Various feature extraction methods have been proposed in the literature. In this study, we present a novel fiducial point extraction algorithm to detect c and d points from the acceleration photoplethysmogram (APG), namely “CnD”. The algorithm allows for the application of various pre-processing techniques, such as filtering, smoothing, and removing baseline drift; the possibility of calculating first, second, and third photoplethysmography derivatives; and the implementation of algorithms for detecting and highlighting APG fiducial points. An evaluation of the CnD indicated a high level of accuracy in the algorithm’s ability to identify fiducial points. Out of 438 APG fiducial c and d points, the algorithm accurately identified 434 points, resulting in an accuracy rate of 99%. This level of accuracy was consistent across all the test cases, with low error rates. These findings indicate that the algorithm has a high potential for use in practical applications as a reliable method for detecting fiducial points. Thereby, it provides a valuable new resource for researchers and healthcare professionals working in the analysis of photoplethysmography signals.

Place, publisher, year, edition, pages
2023. Vol. 12, no 5, article id 1174
National Category
Medical Engineering
Identifiers
URN: urn:nbn:se:mdh:diva-62004DOI: 10.3390/electronics12051174ISI: 000947098400001Scopus ID: 2-s2.0-85149747017OAI: oai:DiVA.org:mdh-62004DiVA, id: diva2:1741084
Available from: 2023-03-03 Created: 2023-03-03 Last updated: 2023-04-12Bibliographically approved

Open Access in DiVA

fulltext(2355 kB)363 downloads
File information
File name FULLTEXT01.pdfFile size 2355 kBChecksum SHA-512
0e99252401888d50242ce954d6453a40478b33acbb2eb44c31e57cf6e4ec13437006d2f221eb2f8ee58cfbbbc41620daee9c8a3db2d05df6a724f19b0238a4aa
Type fulltextMimetype application/pdf

Other links

Publisher's full textScopus

Authority records

Abdullah, SaadFolke, MiaLindén, MariaKristoffersson, Annica

Search in DiVA

By author/editor
Abdullah, SaadHafid, AbdelakramFolke, MiaLindén, MariaKristoffersson, Annica
By organisation
Embedded Systems
In the same journal
Electronics
Medical Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 363 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 1182 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf